4. Remove the left reset lever (2).
5. Remove the right reset lever (3).
6. Lift the back-up (pressure) roller (4) at A and slide it in the direction of arrow B and remove the
roller, using care not to lose the bushings or springs.
7. Remove the fuser roller idle gear (5).
8. Remove the stacker cover damper gear (6).
9. Remove the cover open switch arm from the left reset lever.
10. Remove the stacker cover damper arm (7).
NOTE:
Lubrication
Lightly lubricate the channels of the reset levers, as necessary.
Refer to Section 3.5 of this
Service Handbook for lubrication details
.
P/N 50924201 Spring: Stacker Cover Reset RSPL
B.2.05
P/N 50805801 Lever: Reset (Left) RSPL
B.2.05
P/N 50805901 Lever: Reset (Right) RSPL
B.2.05
P/N 53343701 Roller: Back-up (Pressure) RSPL
B.2.05
P/N 51607601 Bushing: Pressure Roller RSPL
B.2.05
P/N 50924101 Spring: Bias (Pressure Roller)
B.2.05
P/N 51229101 Gear: Fuser Roller Idle RSPL
B.2.05
P/N 51229401 Gear: Stacker Cover Damper RSPL
B.2.05
P/N 53068901 Arm: Cover Open Switch RSPL
B.2.05
P/N 53069101 Arm: Stacker Cover Damper RSPL
B.2.05