Page: 187
Service Guide OF1000
Chapter 4 Failure & Repair Analysis
4.8.03 Fuser Counter Reset
You must reset the Fuser Counter whenever the Fuser Unit is replaced. To reset this counter,
perform the following actions.
1. Press
SELECT FUNCTION.
2. Press
RIGHT ARROW
twice.
3. Press the
"7"
Key.
The following message will be displayed.
7: PRT. COUNTER CLEAR?
YES NO
4. Press
LEFT ARROW
.
5. Press the
"3"
Key.
6. Press
LEFT ARROW
.
The following message will be displayed
ARE YOU SURE?
7. Press
LEFT ARROW
to reset the fuser counter.
8. Press
SELECT FUNCTION
to exit the procedure.
Verify the counter has been RESET as follows.
1. Press
SELECT FUNCTION.
2. Press
RIGHT ARROW.
3. Press the
"8"
Key.
4. Press
LEFT ARROW.
The contents of the counter will be displayed on the LCD for approximately four seconds.
5. Press
STOP
to exit the procedure.
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)