Service Guide OF1000
Chapter 4 Failure & Repair Analysis
4.6.05 High-Speed Modem Transmit Test
This test must be run in conjunction with an Okifax 1000 at a remote location. The remote Okifax
1000 must be set up to run the High Speed Modem Receive Test.
Refer to RAP 12
if the
High-Speed Modem Test should fail.
Procedure
1. Press
SELECT FUNCTION.
2. Press
COPY
twice.
3. Press
LEFT ARROW
twice.
4. Press the
"5"
Key on the ten-key pad.
5. Press
LEFT ARROW.
The following message will be displayed.
H-M/D SEND TEST
9600 01 38" 0000
Where:
9600: Data Transfer Rate
01 38" : Transmission Time in Minutes ( ' ) and Seconds ( " )
0000: Data Transfer Error Counter
6. Press
STOP
four times to exit the test.