4. ADMINISTRATING PRINTERS IN NETWORK
57
Returns the configuration value of
the front tray
Returns the auto-selection lock
status for the front tray(MP tray)
Returns the auto-selection lock
status for the standard cassette
Returns the auto-selection lock
status for the optional cassette
Number of Copies (1-999)
Orientation
Parallel Interface valid/invalid
(Read Only)
RS232C valid/invalid (Read Only)
Network (OKIHSP) valid/invalid
(Read Only)
Print resolution
Receive Buffer size(KB)
Font Cache size
n*100KB
Resource save size
n*100KB
Auto continuation at error occurrence
Paper eject at receive time-out(Sec)
Manual Insert timeout
0: Infinit, 30: 30 sec., 60: 1 min.
Print darkness for mono printer
Time for shifting to Power Save Mode
0: 0Sec, 8: 8Min
Shift to On-line in Toner Low state
Off: remaining On-line
Toner saving
Handling of clearable warning
JOB: Clearing by jobs
Outputing report at error occurrence.
Parallel I/F receiving speed
(Read Onry)
Bi-directional parallel (Read Onry)
105. Prime valid/invalid
On: Valid
Local message language
RS232C Baud Rate (Read Only)
RS232C Data Bit length (Read Only)
RS232C parity (Read Only)
RS232C Minimum Busy time
(Rea Only)
RS232C Flow Control
(Read Only)
(User Maintenance Mode Item)
(User Maintenance Mode Item)
ID
180
190
200
210
220
620
640
650
680
2000
2040
2050
2060
2070
2080
2090
2100
2110
2120
2130
2140
2150
2160
2170
2180
2190
2200
2210
2220
2230
2240
3010
3020
Object Name
cfgMptray
cfgIntray1
cfgIntray2
cfgIntray3
cfgCopies
cfgOrientation
cfgParallel
cfgRs232c
cfgNetwork
cfgResolution
cfgOkiReceiveBuffer
cfgOkiFontProtection
cfgOkiResourceSave
cfgAutoCont
cfgOkiAutoEject
cfgManualTimeOut
cfgDensity
cfgOkiPowerSaving
cfgLowToner
cfgEconoMode
cfgClearableWarnings
cfgOkiPrintErrors
cfgParallelSpeed
cfgBiDirection
cfgOkiPrime
cfgLang
cfgRs232cBaud
cfgRs232cDataBits
cfgRs232cParity
cfgRs232cBusyTime
cfgRs232cFlowControl
cfgOkiXAdjust
cfgOkiYAdjust
R/W
Selection
Descriptions
CASSETTE
UNLOCKED
UNLOCKED
UNLOCKED
0 to 998
PORTRAIT, LANDSCAPE
ENABLE, DISABLE
ENABLE, DISABLE
ENABLE, DISABLE
300, 600, V1200
AUTO, 8, 20, 50, 100, 1024
AUTO, OFF, n
AUTO, OFF, n
OFF, ON
0, 5 to 300
0, 30, 60
1 to 5
0, 8, DISABLE
OFF, ON
OFF, MEDIUM, LIGHT
JOB, ON
ON, OFF
HIGH, MEDIUM
ENABLE, DISABLE
ON, OFF
Refer to Table 6 Local Message
Language for set values.
300, 600, 1200, 2400, 4800,
9600, 19200
8BITS, 7BITS
NONE, EVEN, ODD
200, 1SEC
DTRHI, DTRLO, XONXOFF,
ROBUSTXON
-2, -1.75, -1.5, -1.25, -1, -0.75, -0.5,
-0.25, 0, 0.25, 0.5, 0.75, 1, 1.25,
1.5, 1.75, 2
-2, -1.75, -1.5, -1.25, -1, -0.75, -0.5,
-0.25, 0, 0.25, 0.5, 0.75, 1, 1.25,
1.5, 1.75, 2
R
R
R
R
R/W
R/W
R
R
R
R/W
R
R
R
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R/W
R/W
R
R
R
R
R
R/W
R/W