User Interface
33
Status Lights
The status lights on the control panel have the following fuctions.
[14] Control Panel Status Lights
[14] Control Panel Status Lights
Control Panel Display
The operator control panel displays the online screen whenever it is not displaying the menu system or presenting error
messages. If you are in the menu system and you press the ONLINE button, the panel displays the online screen thus
confirming you are no longer in the menu system.
The top left corner indicates the current status of the UV lamps. When the lamps are activated the display shows the
percentage of power achieved with an estimate of the time needed to reach operating (curing) temperature. When the lamps
are hot enough the display shows Lamp 100% and printing can begin. After a print is completed, or if the lamps are turned
off in the menu, the display shows "Cooling".
The top right corner of the online screen alternates between displaying the UV lamp temperature (when the lamps are on)
and the status of the vacuum system (either ON or OFF).
Gantry Beacon (BG Model Only)
Whenever the gantry is preparing to move, the green warning beacon located on the top right end of the gantry illuminates
to alert the operator. This is a safety feature that is meant to let the operator know that the table must be clear of all objects
except the media that will be printed on and also to stay clear of the gantry path when it does begin printing.
Reset Button (BG Model Only)
This blue button on the control panel next to the red Emergency Stop button resets the printer after an interlock is triggered
by an open door. It also resets the printer after the Emergency Stop button is pushed. This is for the BG version only. The
regular T220UV printer uses the ACCEPT key to perform a system reset.
Safety Interlocks
The Interlock system is a safety shutdown feature that includes the Emergency Stop button and a system that detects when
the gantry doors are open. Interlock ensures that the gantry doors are not opened except during approved printing or
maintenance procedures. At all other times, opening the gantry doors results in a error message on the operator display panel
and a shutdown of the printer’s electrical system. A reboot is required to recover from an interlock situation.
Note:
Opening gantry doors — other than when authorized by the operator control panel display — or pushing the
Emergency Stop, results in a complete shutdown of the printer’s operating system. The only recovery soluton is a printer
reboot.
Label
Function
ERROR
Indicates a printer problem has occured
CHECK
Flashes in conjunction with operator alert messages (for example, Blotting cloth low or empty).
INK
Indicates a low ink level condition. Display will indicate which color ink to replace with a new bottle.
Содержание Arizona T220UV
Страница 1: ...Arizona T220UV User Guide...
Страница 5: ...5 Arizona T220UV User Guide Chapter 1 Introduction...
Страница 10: ...10 T220UV User Guide...
Страница 11: ...11 Arizona T220UV User Guide Chapter 2 Product Overview...
Страница 15: ...15 Arizona T220UV User Guide Chapter 3 Safety Information...
Страница 30: ...30 T220UV User Guide...
Страница 31: ...31 Arizona T220UV User Guide Chapter 4 User Interface...
Страница 40: ...40 T220UV User Guide...
Страница 41: ...41 Arizona T220UV User Guide Chapter 5 How to Operate the Arizona T220UV...
Страница 63: ...63 Arizona T220UV User Guide Chapter 6 Ink System Management...
Страница 71: ...71 Arizona T220UV User Guide Chapter 7 Media Management...
Страница 77: ...77 Arizona T220UV User Guide Chapter 8 Error Handling and Troubleshooting...
Страница 92: ...92 T220UV User Guide...
Страница 93: ...93 Arizona T220UV User Guide Chapter 9 Printer Maintenance...
Страница 114: ...114 T220UV User Guide...