• All source reads and destination writes must be configured to the natural boundary of
the programmed transfer size respectively.
• In fixed arbitration mode, a configuration error is caused by any two channel
priorities being equal. All channel priority levels must be unique when fixed
arbitration mode is enabled.
NOTE
When two channels have the same priority, a channel
priority error exists and will be reported in the Error Status
register. However, the channel number will not be reported
in the Error Status register. When all of the channel
priorities within a group are not unique, the channel
number selected by arbitration is undetermined.
To aid in Channel Priority Error (CPE) debug, set the Halt
On Error bit in the DMA’s Control Register. If all of the
channel priorities within a group are not unique, the DMA
will be halted after the CPE error is recorded. The DMA
will remain halted and will not process any channel service
requests. Once all of the channel priorities are set to unique
numbers, the DMA may be enabled again by clearing the
Halt bit.
• If a scatter/gather operation is enabled upon channel completion, a configuration
error is reported if the scatter/gather address (DLAST_SGA) is not aligned on a 32-
byte boundary.
• If minor loop channel linking is enabled upon channel completion, a configuration
error is reported when the link is attempted if the TCDn_CITER[E_LINK] bit does
not equal the TCDn_BITER[E_LINK] bit.
If enabled, all configuration error conditions, except the scatter/gather and minor-loop
link errors, report as the channel activates and asserts an error interrupt request. A scatter/
gather configuration error is reported when the scatter/gather operation begins at major
loop completion when properly enabled. A minor loop channel link configuration error is
reported when the link operation is serviced at minor loop completion.
If a system bus read or write is terminated with an error, the data transfer is stopped and
the appropriate bus error flag set. In this case, the state of the channel's transfer control
descriptor is updated by the eDMA engine with the current source address, destination
address, and current iteration count at the point of the fault. When a system bus error
occurs, the channel terminates after the next transfer. Due to pipeline effect, the next
transfer is already in progress when the bus error is received by the eDMA. If a bus error
Chapter 20 Enhanced Direct Memory Access (eDMA)
K32 L2A Reference Manual, Rev. 2, 01/2020
NXP Semiconductors
459
Содержание K32 L2A Series
Страница 2: ...K32 L2A Reference Manual Rev 2 01 2020 2 NXP Semiconductors...
Страница 42: ...K32 L2A Reference Manual Rev 2 01 2020 42 NXP Semiconductors...
Страница 122: ...Flash Memory Clock K32 L2A Reference Manual Rev 2 01 2020 122 NXP Semiconductors...
Страница 146: ...Module operation in low power modes K32 L2A Reference Manual Rev 2 01 2020 146 NXP Semiconductors...
Страница 158: ...Debug and security K32 L2A Reference Manual Rev 2 01 2020 158 NXP Semiconductors...
Страница 174: ...Module Signal Description Tables K32 L2A Reference Manual Rev 2 01 2020 174 NXP Semiconductors...
Страница 246: ...Application information K32 L2A Reference Manual Rev 2 01 2020 246 NXP Semiconductors...
Страница 322: ...Kinetis Bootloader Status Error Codes K32 L2A Reference Manual Rev 2 01 2020 322 NXP Semiconductors...
Страница 344: ...Application initialization information K32 L2A Reference Manual Rev 2 01 2020 344 NXP Semiconductors...
Страница 374: ...CMP Trigger Mode K32 L2A Reference Manual Rev 2 01 2020 374 NXP Semiconductors...
Страница 384: ...Functional description K32 L2A Reference Manual Rev 2 01 2020 384 NXP Semiconductors...
Страница 592: ...Application Information K32 L2A Reference Manual Rev 2 01 2020 592 NXP Semiconductors...
Страница 602: ...Initialization and application information K32 L2A Reference Manual Rev 2 01 2020 602 NXP Semiconductors...
Страница 656: ...Functional Description K32 L2A Reference Manual Rev 2 01 2020 656 NXP Semiconductors...
Страница 664: ...Functional Description K32 L2A Reference Manual Rev 2 01 2020 664 NXP Semiconductors...
Страница 744: ...Functional description K32 L2A Reference Manual Rev 2 01 2020 744 NXP Semiconductors...
Страница 762: ...Functional description K32 L2A Reference Manual Rev 2 01 2020 762 NXP Semiconductors...
Страница 806: ...Functional description K32 L2A Reference Manual Rev 2 01 2020 806 NXP Semiconductors...
Страница 868: ...Integer square root K32 L2A Reference Manual Rev 2 01 2020 868 NXP Semiconductors...
Страница 976: ...Functional description K32 L2A Reference Manual Rev 2 01 2020 976 NXP Semiconductors...
Страница 1012: ...Functional description K32 L2A Reference Manual Rev 2 01 2020 1012 NXP Semiconductors...
Страница 1094: ...Functional description K32 L2A Reference Manual Rev 2 01 2020 1094 NXP Semiconductors...
Страница 1132: ...Functional description K32 L2A Reference Manual Rev 2 01 2020 1132 NXP Semiconductors...
Страница 1182: ...Functional description K32 L2A Reference Manual Rev 2 01 2020 1182 NXP Semiconductors...
Страница 1290: ...Functional description K32 L2A Reference Manual Rev 2 01 2020 1290 NXP Semiconductors...
Страница 1344: ...USB Voltage Regulator Module Signal Descriptions K32 L2A Reference Manual Rev 2 01 2020 1344 NXP Semiconductors...
Страница 1356: ...Initialization Application Information K32 L2A Reference Manual Rev 2 01 2020 1356 NXP Semiconductors...