NovaTec
Mobile Gateway S20
Picture 37:
CCU-3 status display
LED is off
LED is flashing intermittently
LED is constantly on
CCU
V24
Trunk and terminal equipment
interfaces
Row A
Row C
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
Reset button
Status display (LED)
Ethernet connection speed indicator
Data transfer indicator
Power
Ready
LED
1
2
3
4
5
6
7
8
LED
Reset and CPU not yet started
CPU started
(Sequentially flashing light, turning from left to right.) Boot monitor active
(Power - LED is off) System is in default configuration
System is in operation
Error during CPU self-test 1 (system stops)
Error during CPU self-test 2 (system stops)
CPU-Chipset initializing
Error during bootcode RAM-test (system stops)
CPU creates the stack for switching to protected mode
CPU switches to protected mode
CCU-Hardware is not released (system stops)
System is waiting for the boot monitor respectively the default configuration
(if you press the reset button now, system starts in default configuration)
Error within checksum test of the boot ROM (system stops)
There is not enough DRAM mounted (system stops)
Error in DRAM (system stops)
System is waiting for release of the reset button and after the system has noticed this the default
configuration starts
Loading the default configuration
Loading the boot monitor
The LED 1-8 shows the status of the interfaces.
Ethernet connection speed indicator
Off
green
orange
flashing
Data Transfer indicator
Off
yellow
no active connection to a network
10 Mbit connection active
100 MBit connection active
Error detected, see Logbook for
further informations
no Data Transfer between CCU-3 and Host
Receiving or Transmitting Data's
IP-Adress in default mode: 192.168.127.254