![Nordson Encore HD iControl System Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/nordson/encore-hd-icontrol-system/encore-hd-icontrol-system_hardware-manual_1704337045.webp)
Troubleshooting
4-5
Part 1603054-02
E
2015 Nordson Corporation
Refer to
Page
Description
Message Text
Code
1008
Reverse End of Travel Limit
The machine is at the reverse end of travel
limit.
1112
Positioner not in ready state
for Color Change
The positioner has not reached the proper
location for color change.
200x, 210x
Reciprocator
2001
E-Stop Open
The E-Stop circuit is open.
2002
Encoder failure
The encoder is not responding when motion is
commanded or is responding with defective
signals.
2003
Motor Protector
The motor protector is open.
2004
Motion Controller
The motion controller indicates a failure.
2005
Forward Contactor
The forward contactor did not engage.
2006
Reverse Contactor
The reverse contactor did not engage.
2007
Forward End of Travel Limit
The machine is at the forward end of travel
limit.
2008
Reverse End of Travel Limit
The machine is at the reverse end of travel
limit.
2101
Part size less than minimum
The part detected is too small. The
reciprocator will attempt to stroke at the
minimum length.
2102
Lead gun not defined
−
using
gun 1
The lead gun on the reciprocator is not
defined.
2103
Trail gun not defined
−
using
gun 1
The trailing gun on the reciprocator is not
defined.
2104
Trail gun less than lead
−
trail = lead
The trailing gun number is less than the lead
gun number.
2105
Pattern width not set
−
using
12 inches (305 mm)
The pattern width has not been set using
default.
2106
Vertical scanner not
configured
−
recip mode 1
invalid
A vertical scanner is required for variable
stroke operation.
2107
Speed calculated less than
minimum
The speed of the reciprocator is less than the
minimum value allowed.
2108
Speed calculated greater
than maximum
The speed of the reciprocator is greater than
the maximum value allowed.
2113
Reciprocator not in ready
state for Color Change
The reciprocator is not in the proper position
for color change.
300x
Watchdog
3100
Positioner Watchdog fault
The remote Ethernet device did not respond
with a watchdog signal in 1 second.
3200
Reciprocator Watchdog fault
The remote Ethernet device did not respond
with a watchdog signal in 1 second.
Continued...
Obsolete
Содержание Encore HD iControl System
Страница 4: ...Change Record ii Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 8: ...Table of Contents vi Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 22: ...System Overview 2 10 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 40: ...Installation 3 18 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 88: ...Parts 6 10 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 89: ...Wiring Diagrams 7 1 Part 1603054 02 E 2015 Nordson Corporation Section 7 Wiring Diagrams O b s o l e t e ...
Страница 90: ...Wiring Diagrams 7 2 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 92: ...O b s o l e t e ...