Installation
3-11
Part 1603054-02
E
2015 Nordson Corporation
Switching Inputs to Sourcing
Inputs to I/O card in the iControl console are configured as sinking. 24 Vdc
is applied to all HI terminals. To switch the inputs to sourcing:
1. Disconnect all wires from the I/O card LO terminals, except terminal 24.
Do not remove the blue and white wires from terminals 24 HI and 24 LO.
2. Move the 6-pole jumpers from the HI terminals to the LO terminals.
3. Install the red wire jumpers to connect all 6-pole jumpers together.
4. Connect the red wire from the 25-conductor cable to terminal 1 LO.
5. Connect the remaining wires to the HI terminals.
6. At the PEJB, connect the red wire to the (
−
) terminal.
Conveyor Encoder Connections
Bring the encoder cable into the Photoeye Junction Box (PEJB) through a
dust-tight conduit at one of the unused knockouts in the PEJB. Wire the
cable to the encoder and PEJB terminal strip as shown on the PEJB
drawing in Section 7.
Photoeye Connections and Configuration
Connect SO cable to the photoeyes and photoeye junction box terminal
block as shown on the PEJB drawing. Route the cables through the cord
grips installed in the PEJB as shown.
Configure the photoeyes and set their sensitivity as shown on the PEJB
drawing.
Scanner Cable Connections
See Figure 3-6. The photoeye junction box and scanner junction boxes are
shipped with the scanner cables pre-wired to the junction boxes. The
scanner controllers are programmed at the factory according to the system
order specifications. Refer to your system plan views when locating the part
ID stand and scanners or photoeyes. The scanners must be mounted with
the cable ends oriented as shown.
Discrete Scanner Connections
S
Single Zone Scanner: SCNR1 cables to scanner.
S
Dual Zone Scanners: SCNR1 cables to upper scanner, SCNR2 cables
to lower scanner.
S
Part ID Scanner and Zone Scanner: SCNR1 cables to zone scanner,
SCNR2 cables to Part ID scanner.
NOTE:
The part ID scanner or photoeyes must be located so that the
iControl system receives the part ID before the leading edge of the part
breaks the zone scanners or photoeyes.
Obsolete
Содержание Encore HD iControl System
Страница 4: ...Change Record ii Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 8: ...Table of Contents vi Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 22: ...System Overview 2 10 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 40: ...Installation 3 18 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 88: ...Parts 6 10 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 89: ...Wiring Diagrams 7 1 Part 1603054 02 E 2015 Nordson Corporation Section 7 Wiring Diagrams O b s o l e t e ...
Страница 90: ...Wiring Diagrams 7 2 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 92: ...O b s o l e t e ...