Troubleshooting
4-32
Part 1603054-02
E
2015 Nordson Corporation
Calibration with a Mouse
(contd)
Use this procedure to recalibrate the touch screen if you cannot touch the
CAL button or the buttons on the iControl screens, or if you install a
program card previously used in another iControl console.
NOTE:
You must shut off console power before connecting or
disconnecting a mouse or keyboard from the iControl PC.
1. Turn off console power.
2. Open the iControl cabinet door and connect a mouse with a PS2
connector to the MOUSE port on left side of the iControl PC.
3. Turn on power and allow the operating system to load. The CAL button
is displayed on the touch screen before the iControl software loads.
4. Use the mouse to move the cursor to the CAL button and click on it.
The touch screen calibration procedure will start.
NOTE:
If you miss the CAL button, allow the iControl software to load,
then, if possible, open the System Configuration screen and touch the
Program Shutdown button. When the operating system shutdown
prompt appears on the screen, touch the Cancel button, then touch the
CAL button. If you cannot touch any buttons on the screen, then you
will have to cycle console power and try again.
5. When the calibration procedure starts, USE YOUR FINGER, NOT THE
MOUSE, to touch the calibration targets, following the instructions on the
screen carefully. When you have completed the calibration procedure,
touch the iControl button to start the iControl software.
6. Test the touch screen calibration, then perform a program shutdown,
turn off console power, and disconnect the mouse.
No Touch Screen Display
Check the following:
S
Check the power LED on the front bezel below the screen. If LED is not
lit then PC is not powered up.
S
Make sure console power switch is on.
S
Open the console door and make sure the PC power switch is on.
Have an electrician check these:
S
Console fuses on the DIN rail, at the incoming power terminals.
S
Unswitched power connections to the fuse blocks.
S
Power supply to the console.
Obsolete
Содержание Encore HD iControl System
Страница 4: ...Change Record ii Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 8: ...Table of Contents vi Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 22: ...System Overview 2 10 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 40: ...Installation 3 18 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 88: ...Parts 6 10 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 89: ...Wiring Diagrams 7 1 Part 1603054 02 E 2015 Nordson Corporation Section 7 Wiring Diagrams O b s o l e t e ...
Страница 90: ...Wiring Diagrams 7 2 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 92: ...O b s o l e t e ...