Installation
3-9
Part 1603054-02
E
2015 Nordson Corporation
ESD Ground Procedures and Equipment
The best protection against ESD is to keep the ground braids as short as
possible and connect them to a central point on the booth base as shown in
the Star diagram. Under normal conditions making Star connections is not
a problem, but in some systems, such as roll-on/roll-off booths, the ground
braids required for a Star connection are too long to be effective against
ESD. In this case, a Daisy Chain ground configuration is acceptable.
Star Grounding
(Preferred)
Daisy-Chain Grounding
(Alternate)
Self-Drilling Screws
Grounding Block
Booth Base
Flat-Braided
Ground Cable
Grounding Block Kit 1067694 Installation
Figure 3-5
ESD Grounding Procedures and Equipment
Always use the special flat braided copper ESD ground cables furnished
with all Nordson spray gun controllers to ground them. The ESD ground
cables should always be attached to the welded booth base, not to a panel,
enclosure, or other component bolted to the base. Keep the cables as short
as possible. If using a grounding block kit, make sure the block is installed
directly to the welded base with the included self-drilling screws.
An ESD grounding block kit is available for connecting the ground braids to
the booth base. The kit contains two 6-position grounding blocks, fasteners,
terminals, and 15 meters (50 feet) of braided ground cable. If additional kits
are required, order:
1067694 Kit, ground bus bar, ESD, 6
−
position, with hardware
Encoder, Zone, and Part ID Connections
A 25-conductor cable carries conveyor encoder and discrete part ID and
zone input signals from the Photoeye Junction Box (PEJB) to the I/O board
in the iControl console. If these inputs are shared by a second booth then
an additional 25-conductor cable is supplied. Table 3-2 lists the
25-conductor cable connections to be made at the terminal strip.
Section 7 contains a system wiring diagram, console wiring diagram, and
diagrams for the junction boxes and control panels listed in Table 3NO TAG.
NOTE:
Refer to your system plan views when locating the part ID stand
and mounting the photoeyes or scanners.
Obsolete
Содержание Encore HD iControl System
Страница 4: ...Change Record ii Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 8: ...Table of Contents vi Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 22: ...System Overview 2 10 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 40: ...Installation 3 18 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 88: ...Parts 6 10 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 89: ...Wiring Diagrams 7 1 Part 1603054 02 E 2015 Nordson Corporation Section 7 Wiring Diagrams O b s o l e t e ...
Страница 90: ...Wiring Diagrams 7 2 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 92: ...O b s o l e t e ...