Installation
3-4
Part 1603054-02
E
2015 Nordson Corporation
iControl Console CAN Address and Termination Settings
The backplane address dipswitches are set at the factory:
1. Network terminator switch SW1-3 is set to CONTINUOUS for both
backplanes.
2. Network address switches SW1-1 and 2 are set to Guns 1
−
16 for the
lower backplane and to 17
−
32 for the upper backplane (if used).
1
2
3
SW1
Open
Rocker switch
Closed
(top in)
Open
(bottom in)
Slide switch
Closed
(on)
Open
1
2
3
SW1
Open
Upper Backplane
Guns 17
−
32
Lower Backplane
Guns 1
−
16
SW1
−
1
SW1
−
2
Closed
Closed
Guns 1
−
16
Closed
Open
Gun 17
−
32
SW1
−
3
Closed: End
Open:
Continuous
Figure 3-2
CAN Network Connections, Console Addresses, and Termination
Manual Gun Controller Addresses
The manual gun controller addresses are set through software. Each
controller must have a unique address. Up to four manual guns can be
included in a system. Refer to the gun controller manual for instructions.
Manual Gun Controller Termination
Manual gun controllers are shipped with their CAN termination switch set to
ON. For each manual gun controller in the system:
1. Open the controller enclosure and locate SW1 on the controller interface
board.
2. Set the TERM switch on SW1 to OFF.
Obsolete
Содержание Encore HD iControl System
Страница 4: ...Change Record ii Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 8: ...Table of Contents vi Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 22: ...System Overview 2 10 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 40: ...Installation 3 18 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 88: ...Parts 6 10 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 89: ...Wiring Diagrams 7 1 Part 1603054 02 E 2015 Nordson Corporation Section 7 Wiring Diagrams O b s o l e t e ...
Страница 90: ...Wiring Diagrams 7 2 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 92: ...O b s o l e t e ...