Troubleshooting
4-24
Part 1603054-02
E
2015 Nordson Corporation
Correction
Message
Error
Code
2003
Motor Protector
Circuit protector limiting current to the reciprocator motor has
failed.
Check mechanical components of reciprocator for proper
operation. Lubricate, repair, or replace components as
needed.
Check motor electrical circuit between protector and motor.
Repair or replace wiring, terminals, or motor control
components as needed.
Reset circuit protector after corrections have been made.
2004
Motion Controller Fault
Motor VFD “ready for operation” feedback signal has failed.
Check the status display on the motor VFD for fault
indications. Status can only be displayed while power is
applied. Cycling power to the VFD will generally reset the fault
condition. Determine the probable cause based on the
controller fault status information.
Correct the problem causing the fault or replace the controller
if necessary.
2005
Up Contactor
Auxiliary contact on the motor forward contactor did not close
when the reciprocator was commanded to move up.
Check up contactor for proper operation. Repair or replace
contactor as needed.
Check control circuit and devices that energize the contactor
for proper operation. Repair or replace components as
needed.
This fault must be reset from the iControl alarm screen.
2006
Down Contactor Fault
Auxiliary contact on the motor down contactor did not close
when the reciprocator was commanded to move down.
Check down contactor for proper operation. Repair or replace
contactor as needed.
Check control circuit and devices that energize the contactor
for proper operation. Repair or replace components as
needed.
This fault must be reset from the iControl alarm screen.
The reciprocator position encoder is not outputting pulses.
NOTE:
If the encoder fails, the reciprocator will stop.
Check all encoder mechanical and electrical connections.
Make sure the encoder is powered.
Check pulse output from the encoder. Replace the encoder if
necessary.
This fault must be reset from the iControl alarm screen.
Continued...
Obsolete
Содержание Encore HD iControl System
Страница 4: ...Change Record ii Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 8: ...Table of Contents vi Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 22: ...System Overview 2 10 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 40: ...Installation 3 18 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 88: ...Parts 6 10 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 89: ...Wiring Diagrams 7 1 Part 1603054 02 E 2015 Nordson Corporation Section 7 Wiring Diagrams O b s o l e t e ...
Страница 90: ...Wiring Diagrams 7 2 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Страница 92: ...O b s o l e t e ...