65
| 11.2019
Commissioning and operation
Rocker circular saw 46-217 and 46-218
WARNING
Risk of injury due to defective motor brake!
A defective motor brake can cause injuries in the event of power
failures as the saw blades cannot be stopped properly.
›
Check the function of the motor brake before every cutting
procedure.
›
To switch the rocker circular saw on:
• Turn the controller (
variant 46-217/230 V
) so that is shows ON
or
• press the green button (
variant 46-218/400 V
) of the switch.
Fig. 11:
Switching on the 46-217 (left) and 46-218 (right) variants
The rocker circular saw starts.
The device is automatically shut down in the event of a power
failure. Press the green button again or turn the controller to
restart.
›
Check the motor brake:
• The saw blade may keep running for some time.
• Switch the device off.
• Measure the time until the saw blade comes to a complete stop.
If the saw blade takes longer than 10 seconds to come to a stop, the
rocker circular saw must not be operated.
i
EN