78
| 11.2019
Faults
Rocker circular saw 46-217 and 46-218
Fault
Cause
Remedy
The rocker circular saw does
not run after a shut down.
The power supply is
interrupted.
›
Check the fuses.
Cable defect.
›
Check the cable.
Dispose of the
defective cable
and do not use it
anymore.
Motor or switch
defect.
›
Have the motor or switch
checked/repaired by an
authorised electrician or
replace it with a genuine
spare part.
The rocker no longer works. The safety hook is not
engaging.
›
Loosen the safety hook
(see “Setting up the
transport protection” on
page 62).
The return spring is
defective.
›
Replace the return spring
(see “Replacing the
return spring” on page
74).
i