4
Applications
68
Total Station DTM-322 Instruction Manual
5.
Sight the prism or reflective sheet and press
[MSR1]
or
[MSR2]
.
Using
[DSP]
to switch between display screens
Press
[DSP]
to switch between the Stakeout display screens. The following screens are
available:
The REF5 screen is only available if the secondary distance unit is set. For more
information, see
.
Every time you press
[DSP]
, the next screen appears. If you press
[DSP]
in the last screen
(REF4 or REF5), the REF1 screen appears.
To store the point and its offset distance information,
press
[ENT]
.
Enter the point name and feature code.
You can also use this screen to change the HT value.
Sample records
CO, 2pt-Ref Pt:16 & Pt:13 Az:311.2932
CO, Sta= -12.6876 Offset= 1.3721 dZ= 0.0971
SS,17,1.0000,6.9202,18.4700,80.3120,15:48:48,2REF-LINE
Sta
Horizontal distance from P1 to the measure point
along the P1-P2 line
O/S
Horizontal offset from the P1-P2 line to the
measured point
dZ
Vertical offset from the P1-P2 line to the measured
point
REF1
REF2
REF3
REF4
Sta
O/S
dZ
X
Y
Z
HA
VA
SD
HA
VD
HD
REF5
HD
VD
SD
Plain view
Side view
PT1
PT2
Sta
O/S
Prism
Prism
PT2
Sta
PT1
dZ
Содержание HQA46480
Страница 1: ...www trimble com Total Station DTM 322 Instruction Manual Version A 1 0 0 Part Number C232E April 2009 ...
Страница 8: ...viii Total Station DTM 322 Instruction Manual ...
Страница 14: ...Contents xiv Total Station DTM 322 Instruction Manual ...
Страница 60: ...3 Getting Started 46 Total Station DTM 322 Instruction Manual ...
Страница 157: ...C H A P T E R 8 Total Station DTM 322 Instruction Manual 143 System Diagrams 8 In this chapter System Components ...
Страница 160: ...8 System Diagrams 146 Total Station DTM 322 Instruction Manual ...
Страница 176: ...9 Communications 162 Total Station DTM 322 Instruction Manual ...