4
Applications
48
Total Station DTM-322 Instruction Manual
HA Reset and Angle Operations
To open the Angle menu, press
[ANG]
in the BMS. To
select a command from this menu, either press the
corresponding number key, or press
[<]
or
[>]
to highlight
the command and then press
[ENT]
.
Setting the horizontal angle to 0
To reset the horizontal angle to 0, press
[1]
or select
0-Set
in the Angle menu. The
display returns to the Basic Measurement Screen (BMS).
Entering the horizontal angle
To display the HA Input screen, press
[2]
or select
Input
in the Angle menu. Use the numeric keys to
enter the horizontal angle. Then press
[ENT]
.
Recording a foresight point after repeat angle measurement
1.
To activate repeat angle measurement, press
[3]
or select
Rept.
in the Angle menu.
HR=0
appears.
2.
Sight the backsight and press
[ENT]
.
3.
Sight the foresight and press
[ENT]
.
The horizontal angle is accumulated and the
value is held again.
4.
To end repeat angle measurement, press
[ESC]
.
5.
When you have accumulated enough horizontal
angle between the backsight and the foresight,
press
[MSR1
] or
[MSR2]
to take a measurement to
the foresight.
To enter 123°45'50", type
[1] [2] [3] [.] [4] [5] [5] [0]
.
The displayed value is rounded to the minimum angle increment.
Содержание HQA46480
Страница 1: ...www trimble com Total Station DTM 322 Instruction Manual Version A 1 0 0 Part Number C232E April 2009 ...
Страница 8: ...viii Total Station DTM 322 Instruction Manual ...
Страница 14: ...Contents xiv Total Station DTM 322 Instruction Manual ...
Страница 60: ...3 Getting Started 46 Total Station DTM 322 Instruction Manual ...
Страница 157: ...C H A P T E R 8 Total Station DTM 322 Instruction Manual 143 System Diagrams 8 In this chapter System Components ...
Страница 160: ...8 System Diagrams 146 Total Station DTM 322 Instruction Manual ...
Страница 176: ...9 Communications 162 Total Station DTM 322 Instruction Manual ...