Total Station DTM-322 Instruction Manual
117
Menu Key
5
–
In the detailed data screen, press the
Edit
softkey.
2.
Use
[^]
or
[v]
to highlight a field. Then modify the
value in the selected field.
3.
To finish editing, press
[ENT]
in the CD field.
A confirmation screen appears.
4.
Do one of the following:
–
To accept the changes and return to the data
view screen, press
[ENT]
or the
Yes
softkey.
–
To go back to the edit screen, press
[ESC]
or
the
No
softkey.
Editing station records
Note – The system will not recalculate measurements if you change the station record.
All coordinate and raw data observed from an edited station record must be
recalculated in your postprocessing software.
In the RAW screen, use
[^]
or
[v]
to highlight the station
record that you want to edit. Then press the
Edit
softkey.
You can edit any field in the ST record, but the
instrument does not recalculate any measurements
from this station.
Press
[ENT]
in the AZ field to confirm the change.
If you change the ST or HI values, the coordinates of observation points are not recalculated. A comment record
is stored to record the change. The following example shows a comment record for a changed HI value:
CO,HI changed at ST:9012 Old HI= 1.3456m
If you change the BS or AZ values, raw records are not recalculated. A comment record is stored to record the
change.
Содержание HQA46480
Страница 1: ...www trimble com Total Station DTM 322 Instruction Manual Version A 1 0 0 Part Number C232E April 2009 ...
Страница 8: ...viii Total Station DTM 322 Instruction Manual ...
Страница 14: ...Contents xiv Total Station DTM 322 Instruction Manual ...
Страница 60: ...3 Getting Started 46 Total Station DTM 322 Instruction Manual ...
Страница 157: ...C H A P T E R 8 Total Station DTM 322 Instruction Manual 143 System Diagrams 8 In this chapter System Components ...
Страница 160: ...8 System Diagrams 146 Total Station DTM 322 Instruction Manual ...
Страница 176: ...9 Communications 162 Total Station DTM 322 Instruction Manual ...