15
GB
5.2) Commissioning
Commissioning can take place only after all testing phases have been
terminated successfully. It is not permissible to execute partial com-
missioning or to enable use of the system in makeshift conditions.
1. Prepare and store for at least 10 years the technical documenta-
tion for the automation, which must include at least: assembly
drawing of the automation, wiring diagram, analysis of hazards
and solutions adopted, manufacturer’s declaration of conformity
of all the devices installed (for SPIN use the annexed CE declara-
tion of conformity); copy of the instruction manual and mainte-
nance schedule of the automation.
2. Post a permanent label or sign near the door detailing the opera-
tions for the release and manual manoeuvre (refer to the figures in
“Instructions and warnings for users of the SPIN gearmotor”).
3. Post a permanent label or sign near the door containing this pic-
ture (min. height 60 mm).
4. Post a label on the door providing at least the following data: type
of automation, name and address of manufacturer (person
responsible for the “commissioning”), serial number, year of man-
ufacture and “CE” marking.
5. Prepare the declaration of conformity of the automation system
and deliver it to the owner.
6. Prepare the “Installation instructions and warnings” of the
automation system and deliver it to the owner.
7. Prepare the maintenance schedule of the automation system and
deliver it to the owner; it must provide all directions regarding the
maintenance of all the automation devices.
Before commissioning the automation system inform the owner in
writing regarding dangers and hazards that are still existing (e.g.
in the “Installation instructions and warnings”).
36
This chapter provides information about how to draw up a maintenance schedule, and the disposal of SPIN.
6) Maintenance and Disposal
6.1) Maintenance
The automation must be subjected to maintenance work on a regu-
lar basis, in order to guarantee it lasts.
The maintenance operations must be performed in
strict compliance with the safety directions provided in
this manual and according to the applicable legislation
and standards.
If other devices are present, follow the directions provided in the cor-
responding maintenance schedule.
1. SPIN requires scheduled maintenance work every 6 months or
3,000 manoeuvres after previous maintenance.
2. Disconnect the power supply
3. Check for any deterioration of the components which form the
automation, paying special attention to erosion or oxidation of
the structural parts. Replace any parts which are below the
required standard.
4. Check the wear and tear on the moving parts: belt, carriage, pin-
ions and the door components; if necessary replace them.
Connect the electric power sources up again, and carry out all
the tests and checks described in paragraph 5.1 “Testing”.
!
6.2) Disposal
SPIN is constructed of various types of materials, some of which can
be recycled: steel, aluminium, plastic, electric cables; while others
must be disposed of (batteries and electronic boards).
Some electronic components may contain polluting
substances; do not pollute the environment. Enquire
about the recycling or disposal systems available in com-
pliance regulations locally in force.
1. Disconnect the power supply of the automation system.
2. Disassemble all the devices and accessories, following in reverse
order the procedures described in chapter 3 “Installation”.
3. Wherever possible, separate any parts which can or must be
recycled or disposed of in different ways, e.g. metal parts must
be disposed of separately from plastic ones, as must the elec-
tronic cards etc.
4. Sort the various materials and consign them to local licensed
firms for recovery and disposal.
!