1.1 - General Warnings

l

 >>> Attention! Important safety instructions. Fol-

low all instructions as improper installation may 

cause serious damage.

l

 >>> Attention! Important safety instructions. It is 

important for you to comply with these instructions 

for your own and other people’s safety. Keep these 

instructions.

l

 

Before commencing the installation, check the “Techni-

cal characteristics” (in this manual), in particular whether 

this product is suitable for automating your guided part. 

If it is not suitable, DO NOT continue with the installation.

l

 

The product cannot be used before it has been com-

missioned

l

 >>> Attention! According to the most recent Euro-

pean legislation, the implementation of an automa-

tion system must comply with the harmonised stand-

ards provided by the Machinery Directive in force, 

which enables declaration of the presumed conform-

ity of the automation. Taking this into account, all op-

erations regarding connection to the electricity grid, 

as well as product testing, commissioning and main-

tenance, must be performed exclusively by a quali-

fied and skilled technician!

l

 

Before proceeding with the installation of the product, 

check that all the materials are in good working order and 

suited to the intended applications.

l

 

This product is not intended to be used by persons (in-

cluding children) whose physical, sensory or mental capac-

ities are reduced, or who lack the necessary experience 

or skill.

l

 

Children must not play with the appliance.

l

 

Do not allow children to play with the fixed control de-

vices of the product. Keep the remote controls away from 

children.

l

 >>> Attention! In order to avoid any danger from in-

advertent resetting of the thermal cut-off device, this 

appliance must not be powered through an external 

switching device, such as a timer, or connected to a 

supply that is regularly powered or switched off by 

the circuit.

l

 

• Provide a disconnection device (not supplied) in the 

plant’s power supply grid, with a contact opening distance 

permitting complete disconnection under the conditions 

dictated by overvoltage category III.

l

 

Handle the product with care during installation, taking 

care to avoid crushing, denting or dropping it, or allowing 

contact with liquids of any kind. Keep the product away 

from sources of heat and naked flames. Failure to observe 

the above can damage the product, and increase the risk 

of danger or malfunction. Should this happen, stop installa-

tion immediately and contact Customer Service.

l

 

The manufacturer assumes no liability for damage to 

property, items or persons resulting from non-compliance 

with the assembly instructions. In such cases the warranty 

for material defects is excluded.

l

 

The weighted sound pressure level of the emission A is 

lower than 70 dB(A).

l

 

Cleaning and maintenance to be carried out by the user 

must not be carried out by unsupervised children.

l

 

Before working on the system (maintenance, cleaning), 

always disconnect the product from the mains power sup-

ply.

l

 

Check the system periodically, in particular all cables, 

springs and supports to detect possible imbalances, signs 

of wear or damage. Do not use, if repairs or adjustments 

are necessary, since installation failure or an incorrectly bal-

anced automation may cause injury.

l

 

The packing materials of the product must be disposed 

of in compliance with local regulations.

l

 

There must be at least 0.4 m between the driven parts 

and any fixed elements.

l

 

The wording on the tubular motors can be covered af-

ter assembly.

l

 

Motor with removable power cable and dedicated con-

nector: if the power cable is damaged, it must be replaced 

by the manufacturer or by the latter’s technical assistance 

service, or by a similarly qualified person, in order to pre-

vent any type of risk.

l

 

Be careful with moving shutters and keep away from 

them until they have lowered fully.

l

 

Do not activate the awning when maintenance activities 

– such as window cleaning – are being carried out nearby.

l

 

Disconnect the awning from the power supply when 

maintenance activities – such as window cleaning – are be-

ing carried out nearby. Warning for ‘shades with automat-

ic control’.

1.2 - Installation warnings

l

 

All product installation and maintenance operations 

must be performed with the automation disconnected from 

the power mains. As a precaution, affix a notice with the 

text “WARNING: MAINTENANCE IN PROGRESS” on the 

disconnect device.

l

 

Prior to installing the drive motor, remove any unneces-

sary cables and disable any appliance not required for mo-

torised operation.

l

 

Make sure that the control devices are kept far from 

moving parts but nonetheless in a visible position.

l

 

Unless a selector is used, the control devices must be 

installed at a height of at least 1.5 m and must not be ac-

cessible.

l

 

The fixed control devices must be installed in a visible 

position.

l

 

For drive motors that allow for accessing unprotected 

moving parts once they have been installed, such parts 

must be installed 2.5 m above the floor or other surface 

form which they can be accessed. 

l

 

l If the product is installed at a height of less than 2.5 m 

from the floor or other support surface, the moving parts 

must be protected with a suitable covering, to avoid inad-

vertent access. For protection, refer to the instruction man-

ual of the shutter, ensuring that future access for mainte-

nance purposes is guaranteed.

l

 

During installation, handle the product with care, avoid-

ing the risk of crushing, impact, dropping or contact with 

any type of liquid, do not insert sharp objects in the motor, 

do not drill or insert screws on the motor exterior and do 

not place the product in the vicinity of heat sources or na-

ked flames (

fig. 2

). This may damage product and cause 

malfunctions, fire or hazardous situations. If this occurs, 

suspend installation immediately and contact the Nice 

Technical Assistance.

l

 

Do not disassemble the product in excess of the opera-

tions envisaged in this manual.

l

 

Never make any modifications to part of the product oth-

ENGLISH

Translation of the original instructions in full

Содержание E M PC

Страница 1: ...ctions et avertissements pour l installation et l utilisation ES Instrucciones y advertencias para la instalaci n y el uso DE Installierungs und Gebrauchsanleitungen und Hinweise PL Instrukcje i ostrz...

Страница 2: ...ntenance cleaning always disconnect the product from the mains power sup ply l Check the system periodically in particular all cables springs and supports to detect possible imbalances signs of wear o...

Страница 3: ...ceeding with installation verify the following l There are various versions of this product available each designed to manage a specific motor torque Each is de signed to automate shutters awnings scr...

Страница 4: ...be powered permanent ly via a permanent connection electrical ma ins consult da ta on the rating plate for motor To connect the motor to a control pushbutton panel and electrical mains refer to fig 5...

Страница 5: ...maximum l Protection rating IP 44 tubular motor l Minimum operating temperature 20 C l Connection cable length 2 m Notes All technical specifications stated in this section refer to an ambient temper...

Страница 6: ...zzatore non deve essere effettuata da bambi ni senza sorveglianza l Prima degli interventi sull impianto manutenzione puli zia disconnettere sempre il prodotto dalla rete di alimen tazione l Verificar...

Страница 7: ...allazione ve rificare i seguenti aspetti l Il presente prodotto disponibile in varie versioni cia scuna con una determinata coppia motore Ognuna di queste progettata per automatizzare avvolgibili con...

Страница 8: ...rone Fase elettrica di salita o discesa Nero Fase elettrica di salita o discesa Blu Comune di solito collegato al Neutro Giallo verde Terra collegamento equipotenziale di pro tezione 4 4 Abbinamento d...

Страница 9: ...nzionamento continuo 4 minuti massimo l Grado di protezione IP 44 motore tubolare l Temperatura minima di funzionamento 20 C l Lunghezza cavo di connessione 2 m Note Tutte le caratteristiche tecniche...

Страница 10: ...sion pond r e A est inf rieur 70 dB A l Le nettoyage et la maintenance qui doivent tre effectu s par l utilisateur ne doivent pas tre confi s des enfants sans surveillance l Avant toute intervention m...

Страница 11: ...l durant les op rations d installation et de r glage quand les connexions lectriques ne sont pas encore d finitives il est possible de commander le moteur tubulaire avec l unit TTU fig 6 INSTALLATION...

Страница 12: ...tribution lectrique consulter les donn es dans l tiquette du moteur Pour connecter le moteur un clavier de commande et au secteur se r f rer la fig 5 Les conducteurs du c ble ont la fonction suivante...

Страница 13: ...u dangereuses qui pourraient avoir des effets nuisibles sur l environnement et sur la sant des personnes s ils taient jet s dans la nature Comme l indique le symbole ci contre il est in terdit de jete...

Страница 14: ...el aparato deben ser efectuados por el usuario y no por ni os sin vigilancia l Antes de realizar cualquier operaci n en la instalaci n limpieza mantenimiento hay que desconectar el aparato de la red d...

Страница 15: ...cionar el motor tubular con la unidad TTU fig 6 INSTALACION DEL PRODUCTO 3 3 1 Controles preliminares l mites de empleo Atenci n Antes de comenzar la instalaci n con trole los siguientes aspectos l Es...

Страница 16: ...el cable de conexi n tienen las siguientes funciones Cable Conexi n Marr n Fase el ctrica de subida o bajada Negro Fase el ctrica de subida o bajada Azul Com n generalmente conectado al Neutro Amarill...

Страница 17: ...Atenci n algunas piezas del producto pueden contener sustancias contami nantes o peligrosas que si se las abandonara en el medio ambiente podr an provocar efectos perjudiciales para el mismo medio am...

Страница 18: ...challdruckpegel ist geringer als 70 dB A l Kinder du rfen Reinigung und Wartungsarbeiten die dem Benutzer obliegen nur dann ausu ben wenn sie von einer er wachsenen Person beaufsichtigt werden l Das P...

Страница 19: ...ngen Anwendungslimits Achtung Vor der Installation die folgenden Aspekte pr fen l Dieses Produkt steht in verschiedenen Ausf hrungen zur Verf gung Jede Ausf hrung dient f r ein bestimmtes Dreh moment...

Страница 20: ...erste Endanschlag 0 und dann der Endanschlag 1 einzustellen 01 Die Rolle in die Position 1 verschieben Die Stellschrauben mit den entsprechenden End anschl gen verbinden 02 Stellen Sie sich vor die Ro...

Страница 21: ...dieses Produkt nicht in den Hausm ll geworfen werden Somit m ssen die Regeln der M lltren nung gem den an Ihrem Ort geltenden Vor schriften eingehalten oder das Produkt an den H ndler ausge h ndigt we...

Страница 22: ...o ci za szkody mate rialne lub osobowe powsta e w wyniku nieprzestrzegania in strukcji monta u W takich przypadkach nie ma zastosowa nia r kojmia za wady materialne l Poziom ci nienia akustycznego emi...

Страница 23: ...temperatury do normalnych wa runk w l podczas prac instalacyjnych i regulacyjnych kiedy nie ma jeszcze po czenia do sieci elektrycznej mo na sterowa si ownik jednostk steruj c TTU rys 6 INSTALOWANIE U...

Страница 24: ...ci tablic przycisk w po tej stronie mechanizmu zwijaj cego po kt rej znajduje si kabel elektryczny silnika rurowego oraz kabel zasilania poprowadzony z sieci elek trycznej l Umie ci przyciski na wyso...

Страница 25: ...aszym terytorium Uwaga nie kt re cz ci urz dzenia mog zawiera substancje zanie czyszczaj ce lub niebezpieczne kt re je eli zostan roz rzucone w otoczeniu mog wywiera szkodliwy wp yw na rodowisko i zdr...

Страница 26: ...den die door de ge bruiker kunnen worden uitgevoerd mogen niet worden toever trouwd aan kinderen die niet onder toezicht staan l Voordat u werkzaamheden aan de installatie uitvoert onder houd reinigin...

Страница 27: ...innen het normale bereik ligt l Tijdens de installatie en afstellingswerkzaamheden wan neer er nog geen definitieve elektrische aansluitingen zijn is het mogelijk de motor met de speciale eenheid TTU...

Страница 28: ...rden via een permanente aansluiting op het elektrische dis tributienet controleert de gegevens op het naambord de mo tor Om de motor aan te sluiten op een bedieningsdrukknop penpaneel en het elektrici...

Страница 29: ...ties bevatten die indien ze in het milieu terechtkomen schadelijke effecten kunnen hebben op de om geving of op de gezondheid van personen Zoals aangegeven door het symbool hiernaast is het verboden d...

Страница 30: ...I NL PL DE ES FR IT EN 3 C L N M FUSE 5 6 4 7 a a1 2 E M PC E M PC E M SH E M SH...

Страница 31: ...entual extraction of the connector Per l eventuale estrazione del connettore Pour l ventuelle extraction du connecteur Para la extracci n del conector Zum eventuellen Herausziehen des Steckers Dla ewe...

Страница 32: ...IDV0693A00MM_15 12 18 www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com...

Отзывы: