2-10 Firmware User Guide
1.
Select
LMI Type
(Link Management Type) and press Return. From the pop-up menu, highlight either
ANSI
(Annex D)
,
CCITT (Annex A)
,
LMI
, or
None
. The default is
None
. Press Return.
See
“Frame Relay DLCI configuration” on page 2-11
for instructions.
Specifying the Link Management Type is the first step in configuring Frame Relay.
■
If you select an LMI Type (Link Management Type) other than None, the
T391
option specifies the
number of seconds between the Status Enquir y messages. The default setting is 10.
■
The
N391
option specifies the frequency of full status polls, in increments of the basic (T391) polling
cycle. The default setting is 6.
■
The
N392
option specifies the maximum number of (link reliability, protocol, and sequence number)
error events that can occur within the N393 sliding window. If an N392 threshold is exceeded, the
switch declares the Netopia Router inactive. The default setting is 3.
■
The
N393
option allows the user to specify the width of the sliding N392 monitored event window. The
default setting is 4.
2.
Select
Tx Injection Management
and press Return. From the pop-up menu, highlight
Standard
if you want
the frames on your line that exceed the configured ser vice parameters to be dropped at the router,
Buffered
if you want the frames on your line that exceed the link capacity to be delayed until the link is less
busy, or
None
if you want all of the frames on your line to be transmitted. Press Return.
Note:
If you select
None
as the Tx Injection Management type, the three Tx Injection Management options
listed below will remain hidden. Go to step 4.
If you select
Standard
or
Buffered
as the Tx Injection Management type, then the
Default CIR
,
Bc
, and
Be
values will appear (in the corresponding fields below the Tx Injection Management field) in order for you to
define the parameters of the management algorithm.
■
The
Default CIR
(CIR also referred to as Committed Information Rate) represents the average capacity
available to a given PVC (Permanent Vir tual Circuit) or DLCI (Data Link Connection Identifier). This set-
Frame Relay Configuration
LMI Type... ANSI (Annex D)
T391 (Polling Interval in secs): 10
N391 (Polls/Full Status Cycles): 6
N392 (Error Threshold): 3
N393 (Monitored Event Window): 4
Tx Injection Management... Standard
Default CIR: 64000
Default Bc: 64000
Default Be: 0
Congestion Management Enabled: No
Maximum Tx Frame Size: 1520
Return/Enter goes to new screen.
Enter Information supplied to you by your telephone company.
Содержание 4000 Series
Страница 10: ...x Firmware User Guide Packet header types B 14 Appendix C Binary Conversion Table C 1 Index ...
Страница 18: ...1 8 Firmware User Guide ...
Страница 66: ...2 48 Firmware User Guide ...
Страница 102: ...3 36 Firmware User Guide ...
Страница 130: ...4 28 Firmware User Guide ...
Страница 206: ...7 18 Firmware User Guide ...
Страница 224: ...9 14 Firmware User Guide ...
Страница 274: ...10 50 Firmware User Guide ...
Страница 314: ...Index 6 ...