
9 Devices
Rev. 02/2018
87
Carry out the self test as follows:
1.
Stop the gas supply to the engine.
2.
Purge the engine.
▸
The engine is ready for the self test.
3.
Set the
Cycle Time
(the interval between the two ignitions).
4.
Define via the
Number of Cycles
whether the self test is to run
Unlimited
or whether it should
be ended after a defined number of cycles.
5.
Define whether
All
outputs or only a defined output should be fired during the self test.
6.
Start the self test via the
Start
button.
▸
The self test runs until it is stopped. In the meantime you can inspect the data received
in other views.
7.
End the self test via the
Stop
button.
▸
The self test is concluded.
Timing Adjustment
Via the corresponding buttons, the global ignition timing can be corrected in 0.1° or 0.5°
increments to advance or retard.
Содержание PoewerView3
Страница 1: ...PowerView3 HMI Module Operating Manual P N 01 10 015 EN Rev 02 2018...
Страница 16: ...4 Product Description 16 Rev 02 2018...
Страница 17: ...4 Product Description Rev 02 2018 17...
Страница 18: ...4 Product Description 18 Rev 02 2018...
Страница 19: ...4 Product Description Rev 02 2018 19...
Страница 26: ...4 Product Description 26 Rev 02 2018 4 1 8 Overview Drawings Rear View...
Страница 27: ...4 Product Description Rev 02 2018 27 Plan View Side View...
Страница 137: ...Rev 02 2018 137...
Страница 138: ......