NICE7000 User Manual Introduction
- 5 -
Repeat door close
If the door lock is not applied after the elevator performs door close for a
certain time, the elevator automatically opens the door and then closes
the door again.
Independent
command
When the main and auxiliary operation boxes are configured, they can
independently control door open/close according to the commands in
automatic running state.
Voice announcement
The elevator automatically announces information such as the running
direction and next arriving floor during running.
This function requires use of the MCTC-CHM-B.
Leveling accuracy
adjustment
The leveling accuracy can be adjusted by setting parameters.
Auto-leveling
The systems implements automatic accurate leveling based on the floor
pulse counting and up/down leveling feedback signals.
Response at
acceleration
The system allows the elevator to automatically respond to calls from the
service floors during acceleration.
Idle elevator
returning to base
floor
In automatic running state, the elevator automatically returns to the set
parking floor and waits for passengers if there is no car call or hall call
within the set time.
Landing at another
floor
If the door open time exceeds the door open protection time but the door
open limit signal is still inactive, the elevator closes the door and then
automatically runs to the next landing floor. The system reports fault E55.
Cancellation of
wrong calls
Passengers can press the button consecutively twice to cancel wrong
calls.
Service floor setting You can enable or disable the system service for certain floors flexibly
based on actual requirements.
Time-based floor
service
You can flexibly set the time periods and corresponding service floors or
select the service floors by using the service floor switchover switch.
Independent running
The elevator does not respond to any call, and the door needs to
be closed manually. In the case of group control, the elevator runs
independently out of the group control system.
Attendant running
In attendant state, the running of the elevator is controlled by the
attendant.
Low-speed self-
rescue
When the elevator is in non-inspection state and stops at non-leveling
area, the elevator automatically runs to the leveling area at low speed if
the safety requirements are met, and then opens the door.
Periodic self-check
in standby state
The systems perform self-check on the elevator periodically and records
error information within the set time, ensuring reliability and security of
elevator running.
Waiting floor
indicator
When the elevator arrives at a floor, the hall indicator of this floor
becomes ON, indicating that the elevator has arrived.
Car arrival gong
After the elevator arrives at the destination floor, the CTB gives a prompt
tone.
Hall arrival forecast
indicator
When the elevator will arrive at the destination floor soon, the MCTC-
HCB-B outputs a signal to turn on hall arrival forecast indicator.
Hall arrival gong
After the elevator will arrive at the destination floor soon, the MCTC-
HCB-B outputs a signal to turn on the hall arrival gong.
Содержание NICE7000
Страница 1: ......
Страница 15: ......
Страница 16: ...1 Safety Information and Precautions ...
Страница 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Страница 24: ...2 Product Information ...
Страница 34: ...3 Mechanical and Electrical Installation ...
Страница 71: ...4 Use of the Commissioning Tools ...
Страница 79: ...5 System Commissioning and Functions ...
Страница 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Страница 103: ...6 Function Code Table ...
Страница 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Страница 135: ...7 Description of Function Codes ...
Страница 205: ...8 Troubleshooting ...
Страница 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Страница 225: ...9 EMC ...
Страница 234: ...9 EMC NICE7000 User Manual 232 ...
Страница 237: ......