7 Description of Function Codes NICE7000 User Manual
- 160 -
It is used to set the blinking advance time when the elevator arrives the floor required by the
car call.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F6-13
Parking floor 2 start time
00.00–23.59
0
-
★
F6-14
Parking floor 2 end time
00.00–23.59
0
-
★
F6-15
Parking floor 2
0 to F6-00
0
-
★
The elevator returns to the floor set in F6-15 if idle during the time period set in F6-13 to F6-
14.
Parking floor 2 can also be enabled by using the parking floor switchover switch.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F6-16
Fire emergency floor 2
0 to F6-00
0
-
★
Fire emergency floor 2 set in this parameter is enabled by using the fire emergency floor
switchover switch.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F6-17
Fire emergency function
selection 1
0–65535
1283
-
★
F6-18
Fire emergency function
selection 2
0–65535
1291
-
★
F6-19
Fire emergency function
selection 3
0–65535
17156
-
★
These parameters are used to select the required fire emergency functions. Each bit of the
function code defines a function, as described in the following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the
function is disabled.
The functions defined by the binary bits are described in the following table.
Bit
Function
Description
Default
F6-17 Fire emergency function selection 1
Bit0
Fire emergency 1
door 1 valid
In fire emergency state, the elevator under opposite door
control opens the corresponding door.
1
Bit1
Fire emergency 1
door 2 valid
1
Bit2
Nearest floor for
fire emergency
The elevator arrives at the nearest landing floor and uses
it as the fire emergency floor.
0
Bit3
Opposite
door control
unchanged
Opposite door control in fire emergency state is the same
as that during normal running
0
Содержание NICE7000
Страница 1: ......
Страница 15: ......
Страница 16: ...1 Safety Information and Precautions ...
Страница 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Страница 24: ...2 Product Information ...
Страница 34: ...3 Mechanical and Electrical Installation ...
Страница 71: ...4 Use of the Commissioning Tools ...
Страница 79: ...5 System Commissioning and Functions ...
Страница 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Страница 103: ...6 Function Code Table ...
Страница 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Страница 135: ...7 Description of Function Codes ...
Страница 205: ...8 Troubleshooting ...
Страница 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Страница 225: ...9 EMC ...
Страница 234: ...9 EMC NICE7000 User Manual 232 ...
Страница 237: ......