NICE7000 User Manual 3 Mechanical and Electrical Installation
- 67 -
Table 3-24 Slow-down distances based on different rated elevator speeds
Rated
Elevator
Speed (m/s)
0.25
0.4
0.5
0.63
0.75
1
1.5
1.6
1.75
2
2.5
3
3.5
4
Distance of
Slow-down 1
(m)
0.2
0.2
0.2
0.2
0.4
0.7
1.5
1.7
2.0
2.0
2.0
2.0
2.0
2.0
Distance of
Slow-down 2
(m)
None
2.5
4.0
4.0
4.0
4.0
Distance of
Slow-down 3
(m)
None
6
8
11
•
"V" indicates the elevator speed, and precautions on the actual installation distance are as
follows:
•
V < 1 m/s: The actual installation distances of the slow-down switches should be close to the
values recommended in this table.
• 1 m/s ≤ V ≤ 2 m/s: The actual installation distances of the slow-down switches are allowed to
have an error within ±0.1 m based on the values recommended in this table.
• 2 m/s < V ≤ 4 m/s: The actual installation distances of the slow-down switches are allowed to
have an error within ±0.3 m based on the values recommended in this table.
Note
•
The slow-down distances above are calculated on the basis of the default special deceleration
rate 0.9 m/s
2
.
•
Increasing the special deceleration rate does not affect safety. However, decreasing the special
deceleration rate may bring safety hazard. If any change is in need, re-calculate the slow-down
distance by using the above formula.
3.10.3 Installation of Limit Switches
The up limit switch and down limit switch protect the elevator from over travel top/bottom
terminal when the elevator does not stop at the leveling position of the terminal floor.
•
The up limit switch needs to be installed 30−50 mm away from the top leveling position.
The limit switch acts when the car continues to run upward 30−50 mm from the top
leveling position.
•
The down limit switch needs to be installed 30−50 mm away from the bottom leveling
position. The limit switch acts when the car continues to run downward 30−50 mm from
the bottom leveling position.
Содержание NICE7000
Страница 1: ......
Страница 15: ......
Страница 16: ...1 Safety Information and Precautions ...
Страница 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Страница 24: ...2 Product Information ...
Страница 34: ...3 Mechanical and Electrical Installation ...
Страница 71: ...4 Use of the Commissioning Tools ...
Страница 79: ...5 System Commissioning and Functions ...
Страница 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Страница 103: ...6 Function Code Table ...
Страница 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Страница 135: ...7 Description of Function Codes ...
Страница 205: ...8 Troubleshooting ...
Страница 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Страница 225: ...9 EMC ...
Страница 234: ...9 EMC NICE7000 User Manual 232 ...
Страница 237: ......