5 System Commissioning and Functions NICE7000 User Manual
- 94 -
In parallel mode, the physical floor numbers of the same floor for two elevators are
consistent.
If the floor structures of two elevators are different, physical floors should start with the
floor with the lowest position.
The physical floors at the overlapped area of the two elevators are the same.
Even if one elevator does not stop a floor in the overlapped area, a leveling plate should
be installed there. You can make the elevator not stop at the floor by setting service
floors.
When two elevators are in parallel mode, the addresses of the HCBs should be set
according to physical floors. Parallel running can be implemented only when the HCB
address set for one elevator is the same as that for the other elevator in terms of the
same floor.
Note
In parallel mode, the top floor (F6-00) and bottom floor (F6-01) of the elevators should be set
based on corresponding physical floors.
Assume that there are two elevators in parallel mode. Elevator 1 stops at floor B1, floor 1,
floor 2, and floor 3, while elevator 2 stops at floor 1, floor 3, and floor 4. Now, you need to
set related parameters and HCB addresses according to the following table.
Table 5-7 Parameter setting example of parallel control
Elevator 1
Elevator 2
Number of elevators in
parallel/group mode (Fd-00)
2
2
Elevator No. (Fd-01)
1
2
Actual floor Physical floor
HCB
address
HCB display
HCB address
HCB display
B1
1
1
FE-01 = 1101
/
/
1
2
2
FE-02 = 1901
2
FE-02 = 1901
2
3
3
FE-03 = 1902
Non-stop floor
but leveling plate
required
FE-03 = 1902
3
4
4
FE-04 = 1903
4
FE-04 = 1903
4
5
/
/
5
FE-05 = 1904
Bottom floor (F6-01)
1
2
Top floor (F6-00)
4
5
Service floor (F6-05)
65535
65531 (not stop at physical floor 3)
Содержание NICE7000
Страница 1: ......
Страница 15: ......
Страница 16: ...1 Safety Information and Precautions ...
Страница 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Страница 24: ...2 Product Information ...
Страница 34: ...3 Mechanical and Electrical Installation ...
Страница 71: ...4 Use of the Commissioning Tools ...
Страница 79: ...5 System Commissioning and Functions ...
Страница 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Страница 103: ...6 Function Code Table ...
Страница 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Страница 135: ...7 Description of Function Codes ...
Страница 205: ...8 Troubleshooting ...
Страница 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Страница 225: ...9 EMC ...
Страница 234: ...9 EMC NICE7000 User Manual 232 ...
Страница 237: ......