7 Description of Function Codes NICE7000 User Manual
- 162 -
Bit
Function
Description
Default
Bit8
Fire emergency
indicator blinking
at fire emergency
2
These functions control the fire emergency indicator and
tone in firefighter state.
The following conditions are required to implement the
functions:
Install the HCB-B.
Set the functions of the HCB-B output terminals in group
FL parameters.
Connect the fire emergency components to the
corresponding output terminals.
1
Bit9
Fire emergency
indicator steady
ON at fire
emergency 2
0
Bit10
Fire emergency
tone prompt at
intervals at fire
emergency 2
1
Bit11
Exiting firefighter
operation state at
any floor
If this signal is active, the elevator can exit the firefighter
operation state at any floor.
0
F6-19 Fire emergency function selection 3
Bit0
Nearest call
mode
The elevator responds to the call from the floor nearest
to the current floor first. In addition, the call in the same
direction takes precedence over the call with the same
distance.
Multiple calls can be registered.
This mode has the highest priority.
0
Bit1
First call mode
The elevator responds to the call firstly registered in fire
emergency state. This call can be cancelled by pressing
the button twice.
This mode has the medium priority.
0
Bit2
Last call mode
Only one car call can be registered in firefighter operation
state. The later one overwrites the previous one.
This mode has the lowest priority.
1
Bit3 to
Bit4
Reserved
-
0
Bit5
Call registered
by holding down
button
The car call is registered only when you holding down the
button and release it after door close limit.
0
Bit6
Closing door by
holding down the
door close button
In the fire emergency state, the door close process can
be completed only by holding down the door close button
until the door close limit is reached. Otherwise, it will be
switched over to door open automatically.
0
Bit7
Reserved
-
0
Bit8
Door close at car
call active
In the fire emergency state, the elevator automatically
closes the door when there is a car call.
1
Bit9
Reserved
-
0
Bit10
Reserved
-
0
Bit11
Automatic door
open at arrival
In firefighter operation state, the elevator automatically
opens the door at arrival.
0
Содержание NICE7000
Страница 1: ......
Страница 15: ......
Страница 16: ...1 Safety Information and Precautions ...
Страница 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Страница 24: ...2 Product Information ...
Страница 34: ...3 Mechanical and Electrical Installation ...
Страница 71: ...4 Use of the Commissioning Tools ...
Страница 79: ...5 System Commissioning and Functions ...
Страница 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Страница 103: ...6 Function Code Table ...
Страница 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Страница 135: ...7 Description of Function Codes ...
Страница 205: ...8 Troubleshooting ...
Страница 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Страница 225: ...9 EMC ...
Страница 234: ...9 EMC NICE7000 User Manual 232 ...
Страница 237: ......