8 Troubleshooting NICE7000 User Manual
- 214 -
Fault
Code
Name
Possible Causes
Solution
Level
Err35
Shaft auto-
tuning data
abnormal
1, 10:
Pulse verification is
incorrect or shaft auto-
tuning is not performed.
2: The pulses are
smaller than the base
value; the pulse direction
may be incorrect.
3, 4:
The leveling plate is too
large; the pulse direction
may be incorrect.
5: No leveling signal is
received within 45s shaft
auto-tuning.
7: The leveling signal
remains active within
45s shaft auto-tuning.
8: The floor height
learned by shaft auto-
tuning is too short.
9: The current floor is
not top floor before shaft
auto-tuning ends; the
position of the up slow-
down switch may be
incorrect.
11: Pulse verification is
incorrect.
12: The directions of
up and down leveling
signals are reversed.
101: When shaft auto-
tuning is started, the
elevator is not at the
bottom floor or the down
slow-down is invalid.
102: The system is not
in the inspection state
when shaft auto-tuning
is performed.
103: It is judged upon
power-on that shaft auto-
tuning is not performed.
1.10: Perform shat auto-tuning again.
2, 3, 4, 5, 7, 11:
•
Check whether the elevator
running direction is consistent with
the pulse change in F4-03: F4-
03 increases in up direction and
decreases in down direction. If
not, change the value of F0-05 to
ensure consistency.
•
Check that NO/NC setting of the
leveling sensor is set correctly.
•
Check whether the leveling plates
are inserted properly and whether
there is strong power interference
if the leveling sensor signal blinks.
5: Check whether the running times
out: No leveling signal is received
when the running time exceeds F9-
02.
8: Enable the super short floor
function if the floor distance is less
than 50 cm. If the floor distance is
normal, check installation of the
leveling plate for this floor and check
the sensor.
9: Check whether the setting of
F6-00 (Top floor of the elevator) is
smaller than the actual condition.
12: Check that the up and down
leveling signals are set correctly.
101: Check that the next slow-
down switch is valid, and that F4-01
(Current floor) is set to 1.
102: Check that the inspection switch
is in inspection state.
103: Perform shaft auto-tuning.
4C
Содержание NICE7000
Страница 1: ......
Страница 15: ......
Страница 16: ...1 Safety Information and Precautions ...
Страница 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Страница 24: ...2 Product Information ...
Страница 34: ...3 Mechanical and Electrical Installation ...
Страница 71: ...4 Use of the Commissioning Tools ...
Страница 79: ...5 System Commissioning and Functions ...
Страница 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Страница 103: ...6 Function Code Table ...
Страница 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Страница 135: ...7 Description of Function Codes ...
Страница 205: ...8 Troubleshooting ...
Страница 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Страница 225: ...9 EMC ...
Страница 234: ...9 EMC NICE7000 User Manual 232 ...
Страница 237: ......