3 Mechanical and Electrical Installation NICE7000 User Manual
- 50 -
Terminal
Name
Function
Terminal Wiring
S1
Button for setting the floor address.
Hold down the button to adjust the floor address
(range: 0−56). After you stop pressing, the address
number blinks three times, and therefore the setting
is successful.
S1
CN1
Modbus communication and power supply terminal
Pins 2 and 3 are for Modbus communication. Pins 1
and 4 are for DC power supply.
1 2 3 4
MOD-
MOD+
24V
COM
3.4.6 MCTC-HCB-V1 (6.4-inch Segment LCD Display Board)
Figure 3-10 Appearance, dimensions, and installation method of HCB-V1
184.6
131
160
105
95
135
Φ
4.5
Unit: mm
17.9
14.2
2
MCTC-HCB-V1
1 - Plastic support higher than 1 cm
2 - Self-tapping screw 4-
φ
4.9x30
1
The following table describes the input and output terminals of HCB-V1.
Table 3-11 Input and output terminals of HCB-V1
Terminal
Name
Function
Terminal Wiring
J1
Interface for the up call button and indicator
Pins 2 and 3 are for up call input. Pins 1 and 4 are
power supply for the up call indicator (24 VDC output,
load capacity: 40 mA).
1 2 3 4
Up call indicator
Up call
button
Содержание NICE7000
Страница 1: ......
Страница 15: ......
Страница 16: ...1 Safety Information and Precautions ...
Страница 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Страница 24: ...2 Product Information ...
Страница 34: ...3 Mechanical and Electrical Installation ...
Страница 71: ...4 Use of the Commissioning Tools ...
Страница 79: ...5 System Commissioning and Functions ...
Страница 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Страница 103: ...6 Function Code Table ...
Страница 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Страница 135: ...7 Description of Function Codes ...
Страница 205: ...8 Troubleshooting ...
Страница 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Страница 225: ...9 EMC ...
Страница 234: ...9 EMC NICE7000 User Manual 232 ...
Страница 237: ......