NICE7000 User Manual 7 Description of Function Codes
- 169 -
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F7-01
Up call floor registered
0 to F6-00
0
-
☆
F7-02
Down call floor registered
0 to F6-00
0
-
☆
These parameters are used to set the destination floors at elevator commissioning or
repairing. They can be respectively used as the car call button, hall call up button and hall
call down button. They remain valid after the commissioning command is input, and become
invalid until they are set to 0 or the system suffers power failure.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F7-03
Random running times
0–60000
0
-
☆
It is used to set the random running times of the system.
The NICE7000 has the random automatic running function. If the setting of F7-03 is greater
than 60000, the system keeps implementing random automatic running until you set F7-03
to 0.
You can set the time interval between two times of random running in F7-08.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F7-04
Hall call enabled
0: Yes
1: No
0
-
☆
It is used to enable the hall call function.
0: Yes (hall call allowed)
1: No (hall call forbidden)
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F7-05
Door open enabled
0: Yes
1: No
0
-
☆
It is used to enable the door open function.
0: Yes (door open allowed)
1: No (door open forbidden)
Note
Continuous running of the elevator without door open accelerates overheating of the controller
module. Long-time use in such mode may cause overheat protection, and therefore, use the
function with caution.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F7-06
Overload function
0: Disabled
1: Enabled
0
-
☆
Содержание NICE7000
Страница 1: ......
Страница 15: ......
Страница 16: ...1 Safety Information and Precautions ...
Страница 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Страница 24: ...2 Product Information ...
Страница 34: ...3 Mechanical and Electrical Installation ...
Страница 71: ...4 Use of the Commissioning Tools ...
Страница 79: ...5 System Commissioning and Functions ...
Страница 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Страница 103: ...6 Function Code Table ...
Страница 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Страница 135: ...7 Description of Function Codes ...
Страница 205: ...8 Troubleshooting ...
Страница 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Страница 225: ...9 EMC ...
Страница 234: ...9 EMC NICE7000 User Manual 232 ...
Страница 237: ......