7 Description of Function Codes NICE7000 User Manual
- 188 -
causing incorrect calculation of certain variables and reducing the control effect.
The system automatically performs zero drift detection on the SIN/COS encoder ABCD
analog signals.
If the encoder needs to be replaced after motor auto-tuning, manually clear the zero drift
values first.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
FH-17
Position of up slow-down 1
0.000–300.00
0.00
m
★
FH-18
Position of down slow-down 1 0.000–300.00
0.00
m
★
FH-19
Position of up slow-down 2
0.000–300.00
0.00
m
★
FH-20
Position of down slow-down 2 0.000–300.00
0.00
m
★
FH-21
Position of up slow-down 3
0.000–300.00
0.00
m
★
FH-22
Position of down slow-down 3 0.000–300.00
0.00
m
★
These parameters specify the positions of all slow-down switches relative to the top and
bottom leveling positions.
For the installation positions of the slow-down switches, see the description of section 3.10.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
FH-29
Position switch signal delay
0–200
0
ms
★
It is used to set the delay from receiving the shaft position switch signal to responding.
Group FL: Extension Terminal Function Parameters
Function Code
Parameter Name
Setting Range
Default
Unit
Property
FL-00
CTB input type
0–511
320
-
★
It is used to define the input signal type (NO/NC) of the CTB by binary bit. Each bit of the
function code defines a signal, as described in the following table.
If a bit is set to 1, the signal indicated by this bit is NO input; if this bit is set to 0, this signal
is NC input.
For example, the input signal types of the CTB of an elevator are set as follows:
Bit
Parameter Name
Default
Bit
Parameter Name
Default
Bit0
Door 1 light curtain
0
Bit5
Door 2 close limit
0
Bit1
Door 2 light curtain
0
Bit6
Full-load signal (digital)
1
Bit2
Door 1 open limit
0
Bit7
Overload signal (digital)
0
Bit3
Door 2 open limit
0
Bit8
Light-load signal (digital)
1
Bit4
Door 1 close limit
0
0: NC input; 1: NO input
Convert the binary value to decimal 320, and set it on the operation panel.
Содержание NICE7000
Страница 1: ......
Страница 15: ......
Страница 16: ...1 Safety Information and Precautions ...
Страница 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Страница 24: ...2 Product Information ...
Страница 34: ...3 Mechanical and Electrical Installation ...
Страница 71: ...4 Use of the Commissioning Tools ...
Страница 79: ...5 System Commissioning and Functions ...
Страница 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Страница 103: ...6 Function Code Table ...
Страница 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Страница 135: ...7 Description of Function Codes ...
Страница 205: ...8 Troubleshooting ...
Страница 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Страница 225: ...9 EMC ...
Страница 234: ...9 EMC NICE7000 User Manual 232 ...
Страница 237: ......