NICE7000 User Manual 7 Description of Function Codes
- 145 -
Figure 7-3 Running time sequence
V (speed)
t (time)
F3-18
F3-19
F3-21
F3-20
F2-19
RUN contactor
Brake contactor
Shorting door lock
circuit contactor
Shorting motor
stator contactor
Internal
running status
Leveling signal
RUN contactor feedback
Brake contactor
feedback
Shorting door lock circuit
contactor feedback
Shorting motor
stator contactor
Group F4: Floor Parameters
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F4-00
Leveling adjustment
0–60
30
mm
★
It is used to adjust the leveling accuracy at elevator stop. If over-leveling occurs at all floors
during elevator stop, decrease the value of this parameter properly. If under-leveling occurs
at all floors during elevator stop, increase the value of this parameter properly.
This parameter takes effect to leveling of all floors. Therefore, if leveling at a single floor is
inaccurate, adjust the position of the leveling plate.
If the leveling deviations in up direction and down direction are inconsistent, adjust F4-07
additionally.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F4-01
Current floor
F6-01 to F6-00
1
-
★
This parameter indicates the current floor of the elevator car.
The system automatically changes the value of this parameter during running, and corrects
it at leveling position (door open limit) after the up slow-down and down slow-down switches
act. At non-bottom floor and top-floor leveling, you can also manually modify this parameter,
but the value must be consistent with the actual current floor.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F4-02
High byte of current floor position
0–65535
0
Pulses
●
F4-03
Low byte of current floor position
0–65535
0
Pulses
●
Содержание NICE7000
Страница 1: ......
Страница 15: ......
Страница 16: ...1 Safety Information and Precautions ...
Страница 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Страница 24: ...2 Product Information ...
Страница 34: ...3 Mechanical and Electrical Installation ...
Страница 71: ...4 Use of the Commissioning Tools ...
Страница 79: ...5 System Commissioning and Functions ...
Страница 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Страница 103: ...6 Function Code Table ...
Страница 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Страница 135: ...7 Description of Function Codes ...
Страница 205: ...8 Troubleshooting ...
Страница 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Страница 225: ...9 EMC ...
Страница 234: ...9 EMC NICE7000 User Manual 232 ...
Страница 237: ......