NICE7000 User Manual 6 Function Code Table
- 111 -
Function
Code
Parameter Name
Setting Range
Default
Unit
Property
F6-01
Bottom floor of the
elevator
1 to F6-00
1
-
★
F6-02
Parking floor
F6-01 to F6-00
1
-
★
F6-03
Fire emergency
floor
F6-01 to F6-00
1
-
★
F6-04
Elevator lock floor
F6-01 to F6-00
1
-
★
F6-05
Service floors 1
0–65535
65535
-
★
F6-06
Service floors 2
0–65535
65535
-
★
F6-07
Service floors 3
0–65535
65535
-
★
F6-08
Service floors 4
0–65535
65535
-
★
F6-09
Elevator function
selection 1
Bit0: Disability function
Bit1: Disabling returning to base
floor for verification
Bit2: Re-leveling function
Bit3: Door pre-open function
Bit4: Stuck hall call cancellation
Bit5: Peak service
Bit6: Down collective selective
peak service
Bit7: Fault auto reset
Bit8: Time-based service floor
function
Bit9: Disabling reverse floor
number clear
Bit10: Buzzer not tweet upon re-
leveling
Bit11: Car call deletion
Bit12: Hall call deletion
Bit13: Timed elevator lock
Bit14: Arrival gong disabled at
night
Bit15: Reserved
32768
-
★
Содержание NICE7000
Страница 1: ......
Страница 15: ......
Страница 16: ...1 Safety Information and Precautions ...
Страница 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Страница 24: ...2 Product Information ...
Страница 34: ...3 Mechanical and Electrical Installation ...
Страница 71: ...4 Use of the Commissioning Tools ...
Страница 79: ...5 System Commissioning and Functions ...
Страница 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Страница 103: ...6 Function Code Table ...
Страница 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Страница 135: ...7 Description of Function Codes ...
Страница 205: ...8 Troubleshooting ...
Страница 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Страница 225: ...9 EMC ...
Страница 234: ...9 EMC NICE7000 User Manual 232 ...
Страница 237: ......