NICE7000 User Manual 7 Description of Function Codes
- 141 -
These two parameters are used to set the acceleration time and deceleration time of the
torque current.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F2-20
Current filter coefficient
0.00–40.00
0.00
-
★
It is used to set the current filter time, which suppress the periodic vertical jitter. Increase the
value in ascending order of 3 to achieve the optimum effect.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F2-21
Position lock rollback coefficient
0–9999
0
Pulses
●
It set the rollback pulses at startup.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F2-22
Startup acceleration time
0.000–1.500
0.000
s
★
It is used to set the acceleration time of the startup speed. It is used with F3-00. For details,
see Figure 7-2.
Group F3: Running Control Parameters
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F3-00
Startup speed
0.000–0.030
0.000
m/s
★
F3-01
Startup holding time
0.000–0.500
0.15
s
★
These two parameters are used to set the startup speed and startup speed holding time.
The parameters may reduce the terrace feeling at startup due to static friction between the
guide rail and the guide shoes.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F3-02
Acceleration rate
0.300–1.300
0.600
m/s
2
★
F3-03
Acceleration start jerk time
0.800–3.000
2.500
s
★
F3-04
Acceleration end jerk time
0.800–3.000
2.500
s
★
These parameters are used to set the running curve during acceleration of the elevator.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F3-05
Deceleration rate
0.300–1.300
0.600
m/s
2
★
F3-06
Deceleration end jerk time
0.800–3.000
2.500
s
★
F3-07
Deceleration start jerk time 0.800–3.000
2.500
s
★
These parameters are used to set the running curve during deceleration of the elevator.
F3-02 (F3-05) is the acceleration rate (deceleration rate) in the straight-line acceleration
Содержание NICE7000
Страница 1: ......
Страница 15: ......
Страница 16: ...1 Safety Information and Precautions ...
Страница 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Страница 24: ...2 Product Information ...
Страница 34: ...3 Mechanical and Electrical Installation ...
Страница 71: ...4 Use of the Commissioning Tools ...
Страница 79: ...5 System Commissioning and Functions ...
Страница 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Страница 103: ...6 Function Code Table ...
Страница 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Страница 135: ...7 Description of Function Codes ...
Страница 205: ...8 Troubleshooting ...
Страница 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Страница 225: ...9 EMC ...
Страница 234: ...9 EMC NICE7000 User Manual 232 ...
Страница 237: ......