NICE7000 User Manual 7 Description of Function Codes
- 165 -
Bit
Function
Description
Default
Bit6
Shorting stator
braking mode
switched over to
controller drive
It enables the function of switching over shorting stator
braking mode to controller drive.
0
Bit7
Mode of shorting
stator braking
mode switched
over to controller
drive
0
If the time of the shorting stator braking mode exceeds
30s, the controller starts to drive the elevator.
0
1
If the speed is still smaller than 0.005 m/s after 3s in
the shorting stator braking mode, the controller starts
to drive the elevator.
Bit8
Emergency
evacuation exit
mode
0
The system exits emergency evacuation when
receiving the door open limit signal from the elevator
that arrives at the destination floor.
0
1
The system exits emergency evacuation when
receiving the door close limit signal from the elevator
that arrives at the destination floor.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F6-28
Inspection function selection
0–65535
33
-
★
It is used to select the inspection-related functions. Each bit of the function code defines a
function, as described in the following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the
function is disabled.
The functions defined by the binary bits are described in the following table.
Bit
Function
Description
Default
Bit0
Fire emergency prompt
in inspection state
If the fire emergency signal is active in inspection
state, the controller outputs the arrival gong at
intervals, giving a prompt to the inspection operator.
1
Bit1
Door lock disconnected
after inspection switched
over to normal running
The door lock is additionally disconnected once
when the inspection state is switched over to the
normal running state.
0
Bit2 to
Bit4
Reserved
-
0
Bit5
Door open and close
once after inspection
turned to normal or first-
time power-on
The elevator door opens and closes once after the
system turns from inspection to normal running or
during first-time power-on.
1
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F6-30
VIP function selection
0–65535
0
-
★
It is used to select the elevator VIP function. Each bit of the function code defines a function,
as described in the following table.
Содержание NICE7000
Страница 1: ......
Страница 15: ......
Страница 16: ...1 Safety Information and Precautions ...
Страница 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Страница 24: ...2 Product Information ...
Страница 34: ...3 Mechanical and Electrical Installation ...
Страница 71: ...4 Use of the Commissioning Tools ...
Страница 79: ...5 System Commissioning and Functions ...
Страница 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Страница 103: ...6 Function Code Table ...
Страница 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Страница 135: ...7 Description of Function Codes ...
Страница 205: ...8 Troubleshooting ...
Страница 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Страница 225: ...9 EMC ...
Страница 234: ...9 EMC NICE7000 User Manual 232 ...
Страница 237: ......