These parameters set the percentages for judging overload, full-load, and light-load.
For details, see the descriptions of F8-06 and F8-07.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F8-21
Arrival gong advance time
0–10.0
1.0
s
★
It is used to set the advance time of the arrival gong prompt.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F8-22
Delay upon door open limit
0–2000
1000
ms
★
It is used to set the door open holding time upon door open limit.
It is used together with F6-10 Bit2.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F8-24
Command 2 start address
0–56
0
-
★
It is used to set the start address of the door 2 HCBs when Mod1 is used as the door 2
communication interface.
For details, see section 5.5.3.
Group F9: Time Parameters
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F9-00
Idle time before returning to
base floor
0–240
10
min
★
It is used to set the idle time of the elevator before returning to the base floor.
When the idle time of the elevator exceeds the setting of this parameter, the elevator returns
to the base floor.
If this parameter is set to 0, it becomes invalid.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F9-01
Time for fan and lamp to be
turned off
0–240
2
min
★
It is used to set the time that fan and lamp stays ON before being turned off automatically.
If there is no running command in the automatic running state, the system turns off the fan
and lamp automatically after the time set in this parameter.
If this parameter is set to 0, it becomes invalid.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F9-02
Motor running time limit
0–45
45
s
★
It is used to set the running time limit of the motor.
Содержание NICE7000
Страница 1: ......
Страница 15: ......
Страница 16: ...1 Safety Information and Precautions ...
Страница 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Страница 24: ...2 Product Information ...
Страница 34: ...3 Mechanical and Electrical Installation ...
Страница 71: ...4 Use of the Commissioning Tools ...
Страница 79: ...5 System Commissioning and Functions ...
Страница 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Страница 103: ...6 Function Code Table ...
Страница 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Страница 135: ...7 Description of Function Codes ...
Страница 205: ...8 Troubleshooting ...
Страница 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Страница 225: ...9 EMC ...
Страница 234: ...9 EMC NICE7000 User Manual 232 ...
Страница 237: ......