APPENDICES
Appendix 6 Precautions for Using Serial Communication Module
Appendix 6.2 UINI Instruction
App
- 40
9
PR
OC
ES
S
ING
T
IME
FOR RED
UNDA
NT
S
YSTEM
S
A
P
P
E
NDICE
S
INDE
X
The program example for mode switching is shown in Diagram App.27.
(For the I/O signal is X/Y80 to X/Y9F)
POINT
1. Stop all data communication before mode switching. Data communication will
be stopped when mode switching is performed during data communication.
2. Note that station No. setting change and switching to linked operation/
switching from linked operation to independent mode cannot be made.
Diagram App.27 Program Example
Changes operation mode into MC protocol format 1
Sets transmission specification
Writes mode switching specification contents to
buffer memory
Sets mode switching request
Resets mode switching request signal
Reads error description after switching mode
Completes mode switching
Resets mode switching completion
Clears mode switching request by clear request
Changes setting value of communication protocol
according to communication specifications
Setting value change of buffer memory specific use area
Error processing (LED OFF, error code clear)
0
17
X83
X84
M50
MOV
K1
D0
MOV
H85B0
D1
TO
H8
H90
D0
K2
FROM H8
H203
D2
K1
SET
Y82
RST
Y82
SET
M50
RST
M50
RST
Y82
=
K0
D2
X86
29
M50
32
34
X8E
X60
M11
M12
X52