7.5 Precautions of Programming when Connecting Extension Base
Unit
This section describes the precautions of programming when connecting the extension
base unit.
(1) Precautions for using PX Developer
As for the following functions, use the dedicated instructions. Do not use them to
Ethernet module mounted to the extension base unit.
• Communication control FB (SEND, RECV)
• Event notification
(2) Functions applicable in GX Developer and PX Developer
MELSOFT products connectable to a module mounted on the extension base unit are
GX Developer and PX Developer. However, there are restrictions on applicable
functions.
For details, refer to the following manuals.
GX Developer Version 8 Operating Manual
PX Developer Version 1 Operating Manual (Programming Tool)
(3) Tracking device setting
When tracking device setting is not set, the program is executed using the value
before refresh is performed at the first scan after switching systems
Set the following devices at the tracking device setting.
• Device which performs auto refresh setting to the intelligent function module
mounted on the extension base unit by GX Configurator
• Device that makes auto refresh setting to the CC-Link master module on the
extension base unit
(4) Availability of interrupt pointer
When interrupting from the intelligent function module mounted to the extension base
unit, an interrupt pointer cannot be used.
If set, "CAN'T EXECUTE(I)" (error code: 4225) occurs at the time of start-up.