5
5.5 Tracking Function
5.5.3 Tracking Data
5
- 78
1
OV
ER
VIE
W
2
SYS
TEM
CONFIGURA
TI
ON
3
TR
AC
KI
N
G
C
ABL
E
4
P
R
OCE
DURE
FO
R
S
TAR
TING
UP
A
RE
DUN
DAN
T
S
Y
S
T
E
M
5
RE
DUNDA
NT S
Y
S
T
E
M
FUNCTIONS
6
RE
DUN
DAN
T
S
Y
S
T
E
M
NE
TW
O
R
K
S
7
PR
OG
R
A
MM
IN
G
CA
UTIO
N
S
8
TR
O
U
BLE
S
HOOTING
– :Indicates data that is set to be not tracked by default.
* 1: The number of device points to be used can be changed in the PLC parameter device settings
using GX Developer.
If the number of points to be used is changed, the number after change will be the "default
tracking range" or the "tracking range set by user."
* 2: The number of retentive timer points is 0 by default.
When setting the number of retentive timer points to be used in the PLC parameter device
settings of GX Developer, the set number will be the "default tracking range" or the "tracking
range set by user."
* 3: For the special relays, the data in the range shown in Table5.46 will be automatically tracked:
* 4: For the special registers, the data in the range shown in Table5.47 will be automatically tracked:
* 5: Special relays and special registers used in the redundant system are transferred automatically.
The tracking transfer range cannot be set by the user.
* 6: Do not perform the tracking transfer to the link special relay (SB) and link special register (SW)
used in the network module system since they are the data inherent to stations.
* 7: Refer to Section 7.3 for the processing to be performed when the annunciator is tracked.
Remark
Please use the following settings when changing the internal device settings:
• Bit devices (including timer, retentive timer, counter)
Multiples of 16 of the beginning device number
Transfer range is set in 16 point units
• Word device
Set in 1 point units
Table5.44 Internal Devices That Can Be Tracked
Device
Default Tracking Range
Tracking Range Set by User
Input
X0 to X1FFF
X0 to X1FFF
Output
Y0 to Y1FFF
Y0 to Y1FFF
Internal relay
*1
M0 to M8191
M0 to M8191
Latch Relay
*1
L0 to L8191
L0 to L8191
Step Relay
S0 to S8191
S0 to S8191
Annunciator
*1
–
F0 to F2047
*7
Edge Relay
*1
V0 to V2047
V0 to V2047
Link Relay
*1
B0 to B1FFF
B0 to B1FFF
Link Special Relay
–
SB0 to SB7FF
*6
Timer (Contact Points and Current
Value)
*1
T0 to T2047
T0 to T2047
Retentive Timer (Contact Points and
Current Value)
*2
*2
Counter (Contact Points and Current
Value)
*1
C0 to C1023
C0 to C1023
Data Register
*1
D0 to D12287
D0 to D12287
Link Register
*1
W0 to W1FFF
W0 to W1FFF
Link Special Register
–
SW0 to SW7FF
*6
Index Register
Z0 to Z15
Z0 to Z15
Special Relay
*3
*5
Special Register
*4
*5
File Register
–
ZR0 to ZR1042431