2 General Specifications
MITSUBISHI CNC
36
2.5 Operation Panel I/O Unit
Characteristics of operation panel I/O unit are as follows.
(1)
Number of DI/DO points that can be mounted on the machine operation panel is 64/64 as standard and 96/96 at the
maximum. Both sink and source types are available.
Operation panel I/O unit DI/DO uses equivalent serial link connections as those used for remote I/O.
(2)
Remote I/O interface --- 1ch
Remote I/O unit, scan I/O card, etc. can be extended up to 4 stations.
(a) When FCU7-DX710/711 are used: Up to 4 stations, 128 points/128 points in total, are available.
(b) When FCU7-DX720/721/730/731 are used: Up to 3 stations, 96 points/96 points in total, are available.
(Note)
The maximum number of stations that can be extended is described above whether DI/DO of the
operation panel I/O unit is used or not.
(3)
Manual pulse generator --- 2ch
5V and 12V manual pulse generators can be connected.
(4)
Installation on the back side of the keyboard unit is possible. Allows space saving inside the operation panel.
(Note 1) The station Nos. occupied by the operation panel I/O unit cannot be changed. If the unit has rotary switches,
do not change the switch settings when shipped.
(Settings when shipped: CS1 -> 0/ CS2 -> 1/ CS3 -> 6)
(Note 2) Set the number of DI points that are simultaneously turned ON to be less than half of the total points. If many
points are set to be simultaneously turned ON in high temperature, operation panel I/O unit may be
deteriorated due to the heat.
Classification
Type
Components
Remarks
DI 24V/0V common input
DO Sink output
FCU7-DX710
Base card
Terminator (R-TM)
DI: 64-points 24V/0V common type
DO: 64-points sink type
MPG:2ch
Occupied stations (fixed): 1, 2, 7, 8
RIO3 extensible stations: 3, 4, 5, 6
DI 24V/0V common input
DO Sink output
AO Analog output
FCU7-DX720
Base card
Terminator (R-TM)
Add-on card
DI: 96-points 24V/0V common type
DO: 80-points sink type
MPG:2ch
AO: 1 point
Occupied stations (fixed): 1, 2, 3, 7, 8
RIO3 extensible stations: 4, 5, 6
DI 24V/0V common input
DO Sink output
FCU7-DX730
Base card
Terminator (R-TM)
Add-on card
DI: 96-points 24V/0V common type
DO: 96-points sink type
MPG: 2ch
Occupied stations (fixed): 1, 2, 3, 7, 8
RIO3 extensible stations: 4, 5, 6
DI 24V/0V common input
DO Source output
FCU7-DX711
Base card
Terminator (R-TM)
DI: 64-points 24V/0V common type
DO: 64-points source type
MPG:2ch
Occupied stations (fixed): 1, 2, 7, 8
RIO3 extensible stations: 3, 4, 5, 6
DI 24V/0V common input
DO Source output
AO Analog output
FCU7-DX721
Base card
Terminator (R-TM)
Add-on card
DI: 96-points 24V/0V common type
DO: 80-points source type
MPG:2ch
AO: 1 point
Occupied stations (fixed): 1, 2, 3, 7, 8
RIO3 extensible stations: 4, 5, 6
DI 24V/0V common input
DO Source output
FCU7-DX731
Base card
Terminator (R-TM)
Add-on card
DI: 96-points 24V/0V common type
DO: 96-points source type
MPG:2ch
Occupied stations (fixed): 1, 2, 3, 7, 8
RIO3 extensible stations: 4, 5, 6
Содержание M70V Series
Страница 1: ......
Страница 13: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 25: ......
Страница 26: ...1 1 System Configuration ...
Страница 36: ...11 2 General Specifications ...
Страница 110: ...85 3 Installation ...
Страница 120: ...95 4 Connection ...
Страница 173: ...4 Connection MITSUBISHI CNC 148 ...
Страница 174: ...149 付録 Ap 1 章 149 Appendix 1 Cable ...
Страница 220: ...195 付録 Ap 2 章 195 Appendix 2 EMC Installation Guidelines ...
Страница 232: ...207 付録 Ap 3 章 207 Appendix 3 Restrictions for Lithium Batteries ...
Страница 241: ...Appendix 3 Restrictions for Lithium Batteries MITSUBISHI CNC 216 ...
Страница 242: ...217 付録 Ap 4 章 217 Appendix 4 Precautions for Compliance to UL c UL Standards ...
Страница 246: ......
Страница 250: ......