M70V Series Connection Manual
Appendix 1.14 F023/F024 Cable
165
Appendix 1.14 F023/F024 Cable
Max. cable length: 20m
Application: Manual Pulse Generator (5V spec)
(Note)
Fold the cable shield over the sheath, and wrap copper foil tape over it. Connect the wound copper foil
tape to GND plate of the connector.
[HANDLE]
Connector: 10120-3000VE
Case: 10320-52F0-008
Recommended manufacturer: 3M
Wire material: UL1061-2464
AWG22
×
6P
Recommended manufacturer: Oki
Electric Cable
[1ch][2ch]
Crimp terminal: V1.25-3
Recommended manufacturer: JST
Cable name
1ch
2ch
F023 cable
○
F024 cable
○
○
○
: Usable channel
HANDLE
4
14
10
1
3
13
20
11
5V
GND
5V
GND
1ch
2ch
FG
HANDLE
HA1A
HA1B
HA2A
HA2B