4 Connection
MITSUBISHI CNC
144
4.5 Connection of MITSUBISHI CNC Machine Operation Panel
(Note)
In this chapter "MITSUBISHI CNC Machine operation panel" is shorten to Machine operation panel.
Connect Machine operation panel A to the remote I/O unit I/F of control unit or operation panel I/O unit.
- Machine operation panel A (RIOIN) - cable (FCUA-R211 or SH41) - control unit (RIO1)
- Machine operation panel A (RIOIN) - cable (FCUA-R211 or SH41) - operation panel I/O unit (RIO3)
When supplying power to control unit from Machine operation panel A, the following connection is necessary.
- Machine operation panel A (DCOUT) - cable (G071) - control unit (DCIN)
Connect Machine operation panel B to Machine operation panel A and control unit as follows.
- Machine operation panel B - cable (G460) - Machine operation panel A (SUBP)
- Machine operation panel B - cable (F120) - control unit (EMG)
[When connecting to operation panel I/O unit (RIO3)]
<Related items>
Cable drawing: "Cable: F120 Cable"
"Cable: FCUA-R211 Cable"
"Cable: G460 Cable"
"Cable: SH41 Cable"
"Cable: G011 Cable"
Connector pin assignment: "General Specifications: Operation panel I/O unit" (RIO3 connector/DCIN connector/
DCOUT connector/ RIOIN connector/SUBP connector/EMG connector/CG71 connector)
F120
EMG
FCUA-R211/SH41
G054
DCIN
KEYSW
DCOUT
RIOIN
SUBP
F070
(FCU7-KB926)
(FCU7-KB921)
DC24V
DC24V
FG
F070
EXT
G460
RIO3
CG71
CG71
DCIN
G011
HN232 Card
(Placed on the back of the panel A)
Machine operation panel A
Control Unit
Operation panel I/O Unit
Machine operation panel B
Only when relaying the power G071
When directly providing
the power
Содержание M70V Series
Страница 1: ......
Страница 13: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 25: ......
Страница 26: ...1 1 System Configuration ...
Страница 36: ...11 2 General Specifications ...
Страница 110: ...85 3 Installation ...
Страница 120: ...95 4 Connection ...
Страница 173: ...4 Connection MITSUBISHI CNC 148 ...
Страница 174: ...149 付録 Ap 1 章 149 Appendix 1 Cable ...
Страница 220: ...195 付録 Ap 2 章 195 Appendix 2 EMC Installation Guidelines ...
Страница 232: ...207 付録 Ap 3 章 207 Appendix 3 Restrictions for Lithium Batteries ...
Страница 241: ...Appendix 3 Restrictions for Lithium Batteries MITSUBISHI CNC 216 ...
Страница 242: ...217 付録 Ap 4 章 217 Appendix 4 Precautions for Compliance to UL c UL Standards ...
Страница 246: ......
Страница 250: ......