M70V Series Connection Manual
2.6 Remote I/O Unit
47
2.6 Remote I/O Unit
The following eight types of signals can be input/output from the remote I/O unit (FCUA-DX1xx) according to the type
and No. of contacts. Use serial link connections to connect the unit with the control unit or the operation panel I/O unit.
Multiple remote I/O units can be used as long as the total number of occupied stations is eight or less.
Classification
Type
Components
Remarks
DI 24V/0V common input
DO Sink output
FCUA-DX100
RX311
DI: 32-points 24V/0V common type
(photo coupler insulation)
DO: 32-points sink type (non-insulation)
Number of occupied stations: 1
DI 24V/0V common input
DO Sink output
FCUA-DX110
RX311+RX321-1
DI: 64-points 24V/0V common type
(photo coupler insulation)
DO: 48-points sink type (non-insulation)
Number of occupied stations: 2
DI 24V/0V common input
DO Sink output
AO Analog output
FCUA-DX120
RX311+RX321
DI: 64-points 24V/0V common type
(photo coupler insulation)
DO: 48-points sink type (non-insulation)
AO: 1 point
Number of occupied stations: 2
DI 24V/0V common input
DO Sink output
AI Analog input
AO Analog output
FCUA-DX140
RX311+RX341
DI: 32-points 24V/0V common type
(photo coupler insulation)
DO: 32-points sink type (non-insulation)
AI: 4 points
AO: 1 point
Number of occupied stations: 2
DI 24V/0V common input
DO Source output
FCUA-DX101
RX312
DI: 32-points 24V/0V common type
(photo coupler insulation)
DO: 32-points source type (non-insulation)
Number of occupied stations: 1
DI 24V/0V common input
DO Source output
FCUA-DX111
RX312+RX322-1
DI: 64-points 24V/0V common type
(photo coupler insulation)
DO: 48-points source type (non-insulation)
Number of occupied stations: 2
DI 24V/0V common input
DO Source output
AO Analog output
FCUA-DX121
RX312+RX322
DI: 64-points 24V/0V common type
(photo coupler insulation)
DO: 48-points source type (non-insulation)
AO: 1 point
Number of occupied stations: 2
DI 24V/0V common input
DO Source output
AI Analog input
AO Analog output
FCUA-DX141
RX312+RX341
DI: 32-points 24V/0V common type
(photo coupler insulation)
DO: 32-points source type (non-insulation)
AI: 4 points
AO: 1 point
Number of occupied stations: 2
Содержание M70V Series
Страница 1: ......
Страница 13: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 25: ......
Страница 26: ...1 1 System Configuration ...
Страница 36: ...11 2 General Specifications ...
Страница 110: ...85 3 Installation ...
Страница 120: ...95 4 Connection ...
Страница 173: ...4 Connection MITSUBISHI CNC 148 ...
Страница 174: ...149 付録 Ap 1 章 149 Appendix 1 Cable ...
Страница 220: ...195 付録 Ap 2 章 195 Appendix 2 EMC Installation Guidelines ...
Страница 232: ...207 付録 Ap 3 章 207 Appendix 3 Restrictions for Lithium Batteries ...
Страница 241: ...Appendix 3 Restrictions for Lithium Batteries MITSUBISHI CNC 216 ...
Страница 242: ...217 付録 Ap 4 章 217 Appendix 4 Precautions for Compliance to UL c UL Standards ...
Страница 246: ......
Страница 250: ......