M70V Series Connection Manual
4.2 Connection of Control Unit
117
4.2.9 Connecting with Skip Signal (Sensor)
Connect skip signals to the connector SKIP.
Skip signals are used for processing high-speed signals. Always shield the cable.
(Note)
Connecting the skip signal cable to a wrong connector causes a damage on the control unit when turning ON
the skip signal power supply. Confirm the wiring before turning the power ON.
(1) Connection of skip signal cable
<0V connection at COM terminal>
SKIP
FCUA-R030
Control unit
SKIP
SI8
SI1
SI2
SI3
SI4
SI5
SI6
SI7
FG
0V
1,5,11,15
COM
18
2
12
3
13
7
17
8
FG
24VDC(+)
R030 cable
Stabilized
power supply
0V connection at COM terminal
Control unit