M70V Series Connection Manual
Appendix 2.5 Measures for Wiring in Panel
201
(3) Servo communication cable [SH21 cable]
-
Use a shield clamp within 10cm from the panel's inlet/outlet.
-
When using a ferrite core, install it on both ends of the connected units.
(4) Ethernet cable
-
Use a shielded cable. Use a shield clamp within 10cm from the panel's inlet/outlet.
-
When using a ferrite core, install it on both ends of the connected units.
SH21B
Control panel
cable
Control panel
Control unit
Drive section unit
Shield clamp
Ferrite core
Control panel
Control unit
Shield clamp
Ferrite core
Peripheral device
Ethernet cable
Operation panel