Appendix 1.41 SH41 Cable
Max. cable length: 1m (the maximum length of the cable when connected to the control unit via other units)
Application: Remote I/O cable
between remote I/O,
remote I/O-CNC control unit,
remote I/O-Operation panel I/O unit,
remote I/O-MITSUBISHI CNC machine operation panel A
(between remote I/O units in a panel)
(Note 1) Protect both ends of the cable with insulated bushing.
(Note 2) RIO1 and RIO3 can be used commonly.
(Note 3) Use this cable for short applications, such as bridging the remote I/O units in the same panel. Normally
use the FCUA-R211 cable with high noise withstand level.
[RIO1, RIO2, RIO3]
Connector: 1-178288-3
Contact: 1-175218-2
×
3
Recommended manufacturer:
Tyco Electronics
Wire material:
MVVS 3C
×
0.5mm
2
(MIC 3C
×
0.5mm
2
)
Recommended manufacturer: Takeuchi Densen
Connector: 1-178288-3
Contact: 1-175218-2
×
3
Recommended manufacturer:
Tyco Electronics
RIO1,RIO3(CSH41)
(CSH41)
1
2
3
X
RIO1,RIO3(CSH41)
1
2
3
TXRX
TXRX*
0V
1
2
3
TXRX
TXRX*
0V
(CSH41)
Содержание M70V Series
Страница 1: ......
Страница 13: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 25: ......
Страница 26: ...1 1 System Configuration ...
Страница 36: ...11 2 General Specifications ...
Страница 110: ...85 3 Installation ...
Страница 120: ...95 4 Connection ...
Страница 173: ...4 Connection MITSUBISHI CNC 148 ...
Страница 174: ...149 付録 Ap 1 章 149 Appendix 1 Cable ...
Страница 220: ...195 付録 Ap 2 章 195 Appendix 2 EMC Installation Guidelines ...
Страница 232: ...207 付録 Ap 3 章 207 Appendix 3 Restrictions for Lithium Batteries ...
Страница 241: ...Appendix 3 Restrictions for Lithium Batteries MITSUBISHI CNC 216 ...
Страница 242: ...217 付録 Ap 4 章 217 Appendix 4 Precautions for Compliance to UL c UL Standards ...
Страница 246: ......
Страница 250: ......