M70V Series Connection Manual
4.2 Connection of Control Unit
113
4.2.7 Connecting with I/O Devices via CC-Link
CC-Link unit (FCU7-HN746) works as master station or local station of CC-Link (Ver.2 mode).
Mount the CC-Link unit on the control unit's expansion card slot.
CC-Link uses the dedicated cable. Connect the cable to the terminal block provided with the CC-Link unit.
Make sure to attach the terminator, provided with the CC-Link unit, to the final station unit.
(Note)
CC-Link is an option unit.
(Note 1) Unless the CC-Link dedicated cable is used, CC-Link system does not guarantee its operation. For the
specifications of the CC-Link dedicated cable and the inquiries, see the homepage of the CC-Link Partner
Association (http://www.cc-link.org/). (Click "Product Information".)
(Note 2) Use the terminator provided with the CC-Link unit. The value of the terminator depends on the cable used:
110
Ω
when the CC-Link dedicated cable is used, 130
Ω
when the CC-Link dedicated high performance cable
is used.
(Note 3) Use the FG terminal on the NC side CC-Link terminal block for the connection to the ground of the electric
cabinet.
CC-Link network
connector
FG terminal block
CC-Link cable
Terminal
block
CC-Link remote I/O station
CC-Link unit(FCU7-HN746)
Expansion unit
DA DB DG SLD FG
DA
FG
SLD
DG
DB
DA
FG
SLD
DG
DB
FG
FG
FG
Shielded twisted cable (with 3 wires) (Note 1)
Shielded twisted cable (with 3 wires) (Note 1)
Terminator
(Note 2)
Terminator
(Note 2)
Remote I/O station
terminal block
Remote I/O station
terminal block
NC side CC-Link
unit terminal block
Содержание M70V Series
Страница 1: ......
Страница 13: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 25: ......
Страница 26: ...1 1 System Configuration ...
Страница 36: ...11 2 General Specifications ...
Страница 110: ...85 3 Installation ...
Страница 120: ...95 4 Connection ...
Страница 173: ...4 Connection MITSUBISHI CNC 148 ...
Страница 174: ...149 付録 Ap 1 章 149 Appendix 1 Cable ...
Страница 220: ...195 付録 Ap 2 章 195 Appendix 2 EMC Installation Guidelines ...
Страница 232: ...207 付録 Ap 3 章 207 Appendix 3 Restrictions for Lithium Batteries ...
Страница 241: ...Appendix 3 Restrictions for Lithium Batteries MITSUBISHI CNC 216 ...
Страница 242: ...217 付録 Ap 4 章 217 Appendix 4 Precautions for Compliance to UL c UL Standards ...
Страница 246: ......
Страница 250: ......