4 Connection
MITSUBISHI CNC
104
<Drive unit (MDS-DJ-V1) external emergency stop: Example>
<Caution>
(1)
External emergency stop cannot substitute the emergency stop signal which is input to NC.
It is a function which helps the NC emergency stop.
(2)
When duplicating emergency stop input, wire the NC emergency stop input and the power supply unit external
emergency stop input from the same emergency stop switch.
MDS-DJ-V1
CN9
+24V
EMGIN
LG
FG
EMG
F120
+24V
0V(LG)
MDS-DJ
3
2
1
3
2
1
5
20
EMG
R
R
Stabilized
power supply
Emergency stop input circuit
NC control unit
NC control unit
Emergency
stop switch