M70V Series Connection Manual
4.4 Connection of Remote I/O Unit
139
4.4.4 Connecting FCUA-DX14x Unit with Analog Input/Output Signal
For the analog input/output signal, connect the FCUA-R031 cable to "AIO". Up to four input points and one output point
can be connected for the analog input/output signal. When manufacturing the FCUA-R031 cable, use the FCUA-CS000
connector set (optional, with both ends).
Input/output circuit
CAUTION
1. Connect the cable to the designated connector. Incorrect connections could damage the device.
2. Do not connect or disconnect the connection cables between each unit while the power is ON.
AIO
1
10
11
20
FCUA-R031
FCUA-DX14x
Pin No.
Analog I/F
DAC
220
R
R
150
ADC
AI0
AO
FC UA-DX14x
7
GND
GND
GND
GND
AI1
AI2
AI3
13
12
2
3
150
150
150
1
11
5
15
0V (RG)
0V (RG)
Connector pin No.
Input
Output
Содержание M70V Series
Страница 1: ......
Страница 13: ......
Страница 15: ......
Страница 17: ......
Страница 19: ......
Страница 21: ......
Страница 25: ......
Страница 26: ...1 1 System Configuration ...
Страница 36: ...11 2 General Specifications ...
Страница 110: ...85 3 Installation ...
Страница 120: ...95 4 Connection ...
Страница 173: ...4 Connection MITSUBISHI CNC 148 ...
Страница 174: ...149 付録 Ap 1 章 149 Appendix 1 Cable ...
Страница 220: ...195 付録 Ap 2 章 195 Appendix 2 EMC Installation Guidelines ...
Страница 232: ...207 付録 Ap 3 章 207 Appendix 3 Restrictions for Lithium Batteries ...
Страница 241: ...Appendix 3 Restrictions for Lithium Batteries MITSUBISHI CNC 216 ...
Страница 242: ...217 付録 Ap 4 章 217 Appendix 4 Precautions for Compliance to UL c UL Standards ...
Страница 246: ......
Страница 250: ......