Parameter list
Parameter list
56
Parameter List
Motor const
ant
s
80
Motor capacity
0.1 to 7.5kW, 9999
0.01kW
9999
,
80
50
D0
0
×
82
Motor excitation current
0 to 500A, 9999
0.01A
9999
82
52
D2
0
×
×
83
Motor rated voltage
0 to 1000V
0.1V
200V/400V
∗6
83
53
D3
0
×
84
Rated motor frequency
10 to 120Hz
0.01Hz
50Hz
84
54
D4
0
×
90
Motor constant (R1)
0 to 50
Ω
, 9999
0.001
Ω
9999
90
5A
DA
0
×
96
Auto tuning setting/status
0, 11, 21
1
0
96
60
E0
0
×
PU connector
commun
ication
117
PU communication station number
0 to 31 (0 to 247)
1
0
117
11
91
1
∗7
∗7
118
PU communication speed
48, 96, 192, 384
1
192
118
12
92
1
∗7
∗7
119
PU communication stop bit length
0, 1, 10, 11
1
1
119
13
93
1
∗7
∗7
120
PU communication parity check
0, 1, 2
1
2
120
14
94
1
∗7
∗7
121
Number of PU communication retries
0 to 10, 9999
1
1
121
15
95
1
∗7
∗7
122
PU communication check time interval
0, 0.1 to 999.8s, 9999
0.1s
0
122
16
96
1
∗7
∗7
123
PU communication waiting time setting
0 to 150ms, 9999
1
9999
123
17
97
1
∗7
∗7
124
PU communication CR/LF selection
0, 1, 2
1
1
124
18
98
1
∗7
∗7
—
125
Terminal 2 frequency setting gain
frequency
0 to 400Hz
0.01Hz
50Hz
125
19
99
1
×
—
126
Terminal 4 frequency setting gain
frequency
0 to 400Hz
0.01Hz
50Hz
126
1A
9A
1
×
PID
operation
127
PID control automatic switchover
frequency
0 to 400Hz, 9999
0.01Hz
9999
127
1B
9B
1
128
PID action selection
0, 20, 21, 40 to 43
1
0
128
1C
9C
1
129
PID proportional band
0.1 to 1000%, 9999
0.1%
100%
129
1D
9D
1
130
PID integral time
0.1 to 3600s, 9999
0.1s
1s
,
130
1E
9E
1
131
PID upper limit
0 to 100%, 9999
0.1%
9999
131
1F
9F
1
132
PID lower limit
0 to 100%, 9999
0.1%
9999
132
20
A0
1
133
PID action set point
0 to 100%, 9999
0.01%
9999
133
21
A1
1
134
PID differential time
0.01 to 10.00s, 9999
0.01s
9999
134
22
A2
1
PU
145
PU display language selection
0 to 7
1
1
145
2D
AD
1
×
×
—
146
Parameter for manufacturer setting. Do not set.
146
Parameter for manufacturer setting. Do not set.
C
urren
t
detection
150
Output current detection level
0 to 200%
0.1%
150%
150
32
B2
1
151
Output current detection signal delay
time
0 to 10s
0.1s
0s
151
33
B3
1
152
Zero current detection level
0 to 200%
0.1%
5%
152
34
B4
1
153
Zero current detection time
0 to 1s
0.01s
0.5s
153
35
B5
1
—
156
Stall prevention operation selection
0 to 31, 100, 101
1
0
156
38
B8
1
—
157
OL signal output timer
0 to 25s, 9999
0.1s
0s
157
39
B9
1
—
158
AM terminal function selection
1 to 3, 5, 8 to 12, 14, 21,
24, 52, 53, 61, 62
1
1
158
3A
BA
1
—
160
Extended function display selection
0, 9999
1
9999
160
00
80
2
—
161
Frequency setting/key lock operation
selection
0, 1, 10, 11
1
0
161
01
81
2
×
A
utomati
c r
est
ar
t
functions
162
Automatic restart after instantaneous
power failure selection
0, 1, 10, 11
1
1
162
02
82
2
165
Stall prevention operation level for
restart
0 to 200%
0.1%
150%
165
05
85
2
Func-
tion
Parameter
Name
Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter
Remarks
Instruction Code
Control Mode-based
Correspondence Table
Parameter
Read
Write
Extended
Copy
Clear
All clear
V/F
V/F
V/F
GP MFVC
GP MFVC
GP MFVC
Содержание FR-D700 Series
Страница 11: ...VII MEMO ...
Страница 23: ...12 MEMO ...
Страница 57: ...46 MEMO ...
Страница 262: ...258 MEMO ...
Страница 276: ...272 MEMO ...
Страница 283: ...279 APPENDIX This chapter provides the APPENDIX of this product Always read the instructions before using the equipment ...
Страница 287: ...283 MEMO ...
Страница 289: ......